Brillouin assessment of the crystalline lens in patients with high myopia after long‐term implantable collamer lens V4c implantation
Acta Ophthalmologica · 2025-12 · 103 (8) · 1032-1040
DOI: 10.1111/aos.17435 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Ophthalmologica, online erschienen am 24.12.2024. Verfasst von Yong Ma und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Phakic Intraocular Lenses, Lens, Crystalline, Myopia, Degenerative, Lens Implantation, Intraocular. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Shanghai Rising-Star Program, National Natural Science Foundation of China, Project of Shanghai Science and Technology.
Abstract (Originalsprache)
Purpose
To evaluate the long‐term effects of implantable collamer lens (ICL) V4c on the biomechanical and morphological properties of crystalline lenses in Chinese adults with high myopia using Brillouin microscopy (BM).
Methods
In this case–control study, 102 highly myopic eyes from 102 patients (18–48 years, preoperative spherical equivalent (SE): −6.00–−21.00 D) were categorised into ICL and control groups, matched by age, axial length (AL), lens thickness (LT) and preoperative SE. The biomechanical and morphological properties of the lenses were measured by BM. Ocular and anterior segment parameters, including AL, anterior chamber depth, volume, angle and LT, were assessed using Pentacam and IOL Master 700.
Results
No significant differences were observed in Brillouin morphological parameters between the ICL and control groups, including the width of top plateau (WTP), width of bottom plateau (WBP), bottom‐top (B‐T), slope of anterior cortex (SAC), and slope of posterior cortex (SPC) (all p > 0.05). A slight decrease in biomechanical metrics (height of plateau, Height) was observed in the ICL group, compared with the control group ( p = 0.012). Linear regression analysis revealed age‐related changes in morphological metrics among all participants, including WTP ( p = 0.0001), WBP ( p = 0.0001), and SPC ( p < 0.0001), while B‐T and SAC were age‐independent (both p > 0.05). No age‐related changes in Height were observed ( p > 0.05).
Conclusions
ICL V4c did not significantly alter lens morphology as assessed using BM. A slight decrease in lenticular biomechanics was observed after ICL implantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, China.
- Key Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China.
ORCID-Profile: Jian Cao, Xiaoying Wang, Xingtao Zhou, Jing Zhao
Förderung
- Shanghai Rising-Star Program
- National Natural Science Foundation of China
- Project of Shanghai Science and Technology
- Healthy Young Talents Project of Shanghai Municipal Health Commission
Zitieren
APA
Ma, Y., Cao, J., Yu, Y., Fukuyama, T., Bao, Y., Zhang, Z., Niu, L., Wang, X., Zhou, X., & Zhao, J. (2025). Brillouin assessment of the crystalline lens in patients with high myopia after long‐term implantable collamer lens V4c implantation. Acta Ophthalmologica, 103(8), 1032-1040. https://doi.org/10.1111/aos.17435
Vancouver
Ma Y, Cao J, Yu Y, Fukuyama T, Bao Y, Zhang Z, et al. Brillouin assessment of the crystalline lens in patients with high myopia after long‐term implantable collamer lens V4c implantation. Acta Ophthalmologica. 2025;103(8):1032-1040. doi:10.1111/aos.17435
BibTeX
@article{Ma2025,
author = {Ma, Yong and Cao, Jian and Yu, Yanze and Fukuyama, Teruko and Bao, Yongle and Zhang, Zhe and Niu, Lingling and Wang, Xiaoying and Zhou, Xingtao and Zhao, Jing},
title = {Brillouin assessment of the crystalline lens in patients with high myopia after long‐term implantable collamer lens V4c implantation},
journal = {Acta Ophthalmologica},
year = {2025},
volume = {103},
number = {8},
pages = {1032--1040},
doi = {10.1111/aos.17435}
}
EUVIMED