EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermohydraulic performance of thermal system integrated with twisted turbulator inserts using ternary hybrid nanofluids

Omer A. Alawi, Haslinda Mohamed Kamar, Mayadah W. Falah, Omar A. Hussein, Ali H. Abdelrazek, Waqar Ahmed, Mahmoud Eltaweel, Raad Z. Homod, Nadhir Al-Ansari, Zaher Mundher Yaseen

Nanotechnology Reviews · 04.03.2023 · 12 (1)

DOI: 10.1515/ntrev-2022-0504 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nanotechnology Reviews, online erschienen am 04.03.2023. Verfasst von Omer A. Alawi und 9 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mono, hybrid, and ternary nanofluids were tested inside the plain and twisted-tape pipes using k-omega shear stress transport turbulence models. The Reynolds number was 5,000 ≤ Re ≤ 15,000, and thermophysical properties were calculated under the condition of 303 K. Single nanofluids (Al 2 O 3 /distilled water [DW], SiO 2 /DW, and ZnO/DW), hybrid nanofluids (SiO 2 + Al 2 O 3 /DW, SiO 2 + ZnO/DW, and ZnO + Al 2 O 3 /DW) in the mixture ratio of 80:20, and ternary nanofluids (SiO 2 + Al 2 O 3 + ZnO/DW) in the mixture ratio of 60:20:20 were estimated in different volumetric concentrations (1, 2, 3, and 4%). The twisted pipe had a higher outlet temperature than the plain pipe, while SiO 2 /DW had a lower T out value with 310.933 K (plain pipe) and 313.842 K (twisted pipe) at Re = 9,000. The thermal system gained better energy using ZnO/DW with 6178.060 W (plain pipe) and 8426.474 W (twisted pipe). Furthermore, using SiO 2 /DW at Re = 9,000, heat transfer improved by 18.017% (plain pipe) and 21.007% (twisted pipe). At Re = 900, the pressure in plain and twisted pipes employing SiO 2 /DW reduced by 167.114 and 166.994%, respectively. In general, the thermohydraulic performance of DW and nanofluids was superior to one. Meanwhile, with Re = 15,000, DW had a higher value of η Thermohydraulic = 1.678.

Zitieren

APA

Alawi, O. A., Kamar, H. M., Falah, M. W., Hussein, O. A., Abdelrazek, A. H., Ahmed, W., Eltaweel, M., Homod, R. Z., Al-Ansari, N., & Yaseen, Z. M. (2023). Thermohydraulic performance of thermal system integrated with twisted turbulator inserts using ternary hybrid nanofluids. Nanotechnology Reviews, 12(1). https://doi.org/10.1515/ntrev-2022-0504

Vancouver

Alawi OA, Kamar HM, Falah MW, Hussein OA, Abdelrazek AH, Ahmed W, et al. Thermohydraulic performance of thermal system integrated with twisted turbulator inserts using ternary hybrid nanofluids. Nanotechnology Reviews. 2023;12(1). doi:10.1515/ntrev-2022-0504

BibTeX
@article{Alawi2023,
  author = {Alawi, Omer A. and Kamar, Haslinda Mohamed and Falah, Mayadah W. and Hussein, Omar A. and Abdelrazek, Ali H. and Ahmed, Waqar and Eltaweel, Mahmoud and Homod, Raad Z. and Al-Ansari, Nadhir and Yaseen, Zaher Mundher},
  title = {Thermohydraulic performance of thermal system integrated with twisted turbulator inserts using ternary hybrid nanofluids},
  journal = {Nanotechnology Reviews},
  year = {2023},
  volume = {12},
  number = {1},
  doi = {10.1515/ntrev-2022-0504}
}
Kostenlos starten →