EUVIMEDEUVIMED entdecken
Crossref

Flow dynamics behavior and thermal performance evaluation of double pipe counter flow heat exchanger with twisted tape inserts in the presence of hybrid nanofluids

Prakash H. Jadhav, Pidaparthy Maheshbabu, Ramkumar Ramkrishnan, Goda Sreenivasulu Reddy

Journal of Thermal Engineering · 29.07.2026

DOI: 10.47481/jten.0087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Thermal Engineering, online erschienen am 29.07.2026. Verfasst von Prakash H. Jadhav und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The performance of counter flow heat exchanger is analyzed with and without the insertion of sector cut twisted tape (TT) inserts in the presence of ZnO/MWCNT hybrid nanofluids (HNFs). The sector cut twisted tape inserts is positioned at the exit of tube heat exchanger (HEx). For the analysis, three different concentrations of hybrid nanofluids (0.01%, 0.03% and 0.05%) and three different sector cut twisted tape inserts (5 mm, 7 mm, and 9 mm) are employed. For numerical investigations, a standard two equations k-ɛ model is employed. The novelty of the study is to assess the influence of varying depth of sector cut twisted tape inserts and variations in concentrations of hybrid nanofluids. This study finds application in design and thermal management of engines. The results revealed that, 9 mm sector cut twisted tape inserts with 0.05% concentration of hybrid nanofluids, the augment in heat transfer rate (HTR) by 51.22% higher. Furthermore, performance evaluation criteria (PEC) at higher values of Re number reached to be 2.67, 3.66, 4.598 with the insertion of 5 mm, 7 mm & 9 mm depths of sector twisted tape inserts with 0.05% concentration of hybrid nanofluids.

Zitieren

APA

Jadhav, P. H., Maheshbabu, P., Ramkrishnan, R., & Reddy, G. S. (2026). Flow dynamics behavior and thermal performance evaluation of double pipe counter flow heat exchanger with twisted tape inserts in the presence of hybrid nanofluids. Journal of Thermal Engineering. https://doi.org/10.47481/jten.0087

Vancouver

Jadhav PH, Maheshbabu P, Ramkrishnan R, Reddy GS. Flow dynamics behavior and thermal performance evaluation of double pipe counter flow heat exchanger with twisted tape inserts in the presence of hybrid nanofluids. Journal of Thermal Engineering. 2026. doi:10.47481/jten.0087

BibTeX
@article{Jadhav2026,
  author = {Jadhav, Prakash H. and Maheshbabu, Pidaparthy and Ramkrishnan, Ramkumar and Reddy, Goda Sreenivasulu},
  title = {Flow dynamics behavior and thermal performance evaluation of double pipe counter flow heat exchanger with twisted tape inserts in the presence of hybrid nanofluids},
  journal = {Journal of Thermal Engineering},
  year = {2026},
  doi = {10.47481/jten.0087}
}
Kostenlos starten →