EUVIMEDEUVIMED entdecken
Crossref

An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of meropenem in human serum and plasma

Rupert Schmid, Judith Taibon, Neeraj Singh, Carina Schuster, Arber Rexhaj, Michael Vogeser iD, Friederike Bauland, Andrea Geistanger, Elie Fux

Clinical Chemistry and Laboratory Medicine (CCLM) · 06.08.2026

DOI: 10.1515/cclm-2026-0428 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Chemistry and Laboratory Medicine (CCLM), online erschienen am 06.08.2026. Verfasst von Rupert Schmid und 8 weiteren Autor:innen. Beteiligte Einrichtung: Roche Diagnostics GmbH, Penzberg, Germany. Die Arbeit nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Therapeutic drug monitoring (TDM) of meropenem is critical for optimizing clinical efficacy and minimizing toxicity. We describe the validation of an isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) candidate reference measurement procedure (RMP) for the quantification of meropenem in human serum and plasma.

Methods

A high-purity meropenem standard was characterized using an in-house quantitative nuclear magnetic resonance protocol. This established the absolute content and ensured an unbroken chain of metrological traceability to the International System of Units. Samples were prepared via incubation with a stable isotope-labeled internal standard followed by protein precipitation. Analysis was performed using LC-MS/MS with electrospray ionization. The method was validated to assess selectivity, matrix effects, precision, accuracy, and measurement uncertainty according to international metrological guidelines.

Results

The candidate RMP demonstrated high selectivity across a linear range of 0.400–120 μg/mL and was unaffected by matrix interferences. Intermediate precision was

Schlagwörter

Stichwörter der Autor:innen

SI unitsisotope dilution-liquid chromatography-tandem mass spectrometrymeropenemquantitative nuclear magnetic resonance characterizationreference measurement procedure

Autor:innen und Institutionen

  • Roche Diagnostics GmbH, Penzberg, Germany.
  • Institute of Laboratory Medicine, LMU University Hospital, LMU Munich, Munich, Germany.
  • Evidenze Germany GmbH, Essen, Germany.

ORCID-Profile: Michael Vogeser

Zitieren

APA

Schmid, R., Taibon, J., Singh, N., Schuster, C., Rexhaj, A., Vogeser, M., Bauland, F., Geistanger, A., & Fux, E. (2026). An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of meropenem in human serum and plasma. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2026-0428

Vancouver

Schmid R, Taibon J, Singh N, Schuster C, Rexhaj A, Vogeser M, et al. An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of meropenem in human serum and plasma. Clinical Chemistry and Laboratory Medicine (CCLM). 2026. doi:10.1515/cclm-2026-0428

BibTeX
@article{Schmid2026,
  author = {Schmid, Rupert and Taibon, Judith and Singh, Neeraj and Schuster, Carina and Rexhaj, Arber and Vogeser, Michael and Bauland, Friederike and Geistanger, Andrea and Fux, Elie},
  title = {An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of meropenem in human serum and plasma},
  journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
  year = {2026},
  doi = {10.1515/cclm-2026-0428}
}
Kostenlos starten →