EUVIMEDEUVIMED entdecken
Crossref

A candidate reference measurement procedure based on isotope dilution-liquid chromatography-tandem mass spectrometry for standardizing human serum D-α-tocopherol measurements

Wei Jiang, Bingling Gao, Tao Yang, Liping Tang, Keqi Sun, Peng Xiao

Clinica Chimica Acta · 2026-11 · 122978

DOI: 10.1016/j.cca.2026.122978 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinica Chimica Acta, 2026-11. Verfasst von Wei Jiang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Reference System Center, Maccura Biotechnology Co., Ltd., Chengdu 610219, China. Die Arbeit nennt 37 Literaturangaben. Gefördert von: National Major Science and Technology Projects of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Vitamin E deficiency commonly occurs in infants and often manifests clinically as anemia, edema, nervous system abnormalities, and other symptoms. D-α-tocopherol, the predominant and most biologically active form of vitamin E in human serum. In this study, we developed and validated a candidate reference measurement procedure (cRMP) for human serum D-α-tocopherol using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). METHODS: Isotopically labeled internal was dried under nitrogen at 40 °C before adding appropriate amount of serum sample. The mixture was processed by protein precipitation with methanol and liquid-liquid extraction with n-hexane. The extraction was dried, reconstituted, and analyzed by LC-MS/MS. The cRMP was evaluated according to the Clinical and Laboratory Standards Institute (CLSI) approved guidelines. RESULTS: For samples ranging from 17.0 to 43.6 μmol/L, intra-batch imprecision were below 2.6% and inter-batch imprecision were below 2.0%. The limit of detection and lower limit of measuring interval were determined as 0.0119 and 0.662 μmol/L respectively. Analysis of NIST Standard Reference Material (SRM) 968f resulted in biases of 0.8% for Level 1and 0.5% for Level 2. Recovery rate ranged from 98.1% to 102.5%. Excellent linearity was observed across a range from 0.440 to 78.7 μmol/L. Linear dependency was observed between three clinical routine methods and this cRMP. The method demonstrated good agreement in both method comparison and interlaboratory comparison studies. CONCLUSIONS: A reliable ID-LC-MS/MS-based cRMP was developed, which provided high specificity, accuracy and precision for D-α-tocopherol quantification, contributing to the D-α-tocopherol measurement standardization and traceability.

Schlagwörter

Stichwörter der Autor:innen

D-α-tocopherolID-LC-MS/MSReference measurement procedureTraceability

Autor:innen und Institutionen

  • Reference System Center, Maccura Biotechnology Co., Ltd., Chengdu 610219, China.
  • Reference System Center, Maccura Biotechnology Co., Ltd., Chengdu 610219, China. Electronic address: sunkeqi@maccura.com.
  • Key Laboratory of Chemical Metrology and Applications on Nutrition, Health, State Administration for Market Regulation, Division of Chemical Metrology and Analytical Science, National Institute of Metrology, Beijing 100…

Förderung

  • National Major Science and Technology Projects of China

Zitieren

APA

Jiang, W., Gao, B., Yang, T., Tang, L., Sun, K., & Xiao, P. (2026). A candidate reference measurement procedure based on isotope dilution-liquid chromatography-tandem mass spectrometry for standardizing human serum D-α-tocopherol measurements. Clinica Chimica Acta, 122978. https://doi.org/10.1016/j.cca.2026.122978

Vancouver

Jiang W, Gao B, Yang T, Tang L, Sun K, Xiao P. A candidate reference measurement procedure based on isotope dilution-liquid chromatography-tandem mass spectrometry for standardizing human serum D-α-tocopherol measurements. Clinica Chimica Acta. 2026:122978. doi:10.1016/j.cca.2026.122978

BibTeX
@article{Jiang2026,
  author = {Jiang, Wei and Gao, Bingling and Yang, Tao and Tang, Liping and Sun, Keqi and Xiao, Peng},
  title = {A candidate reference measurement procedure based on isotope dilution-liquid chromatography-tandem mass spectrometry for standardizing human serum D-α-tocopherol measurements},
  journal = {Clinica Chimica Acta},
  year = {2026},
  pages = {122978},
  doi = {10.1016/j.cca.2026.122978}
}