EUVIMEDObjevte EUVIMED
VergleichsstudieRandomisierte kontrollierte StudieOpen access · CC BY 4.0

A comparison of resting metabolic rate measurement in adults, using a ventilated canopy or a mixing‐chamber system with a silicone mask

Yair Pincu iD, F N U Sakshi, Grant A Chesbro, Akram Falahati, Rebecca D Larson

Physiological Reports · 2026-03 · 14 (6)

DOI: 10.14814/phy2.70837 ↗

At a glance

Vergleichsstudie in Physiological Reports, published online on 2026-03-25. Written by Yair Pincu and 4 co-authors. Institution: Department of Health and Exercise Science, University of Oklahoma, Norman, Oklahoma, USA. Major MEDLINE topics: Basal Metabolism, Calorimetry, Indirect, Masks. 28 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

The most common method for measuring resting metabolic rate (RMR) via indirect calorimetry (IC) is using a ventilated canopy system (canopy). Yet, many use a facemask (mask). The purpose of this study was to compare RMR using a canopy and a mask. RMR was measured in 26 participants using a canopy or a mask, followed immediately by the opposite mode in a randomized fashion. RMR was compared between the canopy and mask in males and females using a 2 × 2 repeated‐measures ANOVA. Agreement between the 2 modes and typical error of measurement (TEM) were calculated. Data are mean ± SD. Resting VO 2 and RER were significantly different (VO 2 = 3.72 ± 0.70 vs. 3.46 ± 0.56 mL/kg/min; RER = 0.75 ± 0.04 vs. 0.80 ± 0.04 in canopy vs. mask, p < 0.05). RMR was lower using the mask (1719.71 ± 377.43 vs. 1791.23 ± 387.61 kcal/day, p = 0.026). Mask and canopy RMR showed poor agreement (95% Limit of agreement = −363.5 to 220.5 kcal/day). TEM was larger than the bias between the 2 methods (105.33 kcal/day), which suggests significant random error. Males ( n = 14) had a larger and females ( n = 12) smaller difference in RMR between canopy and mask (−79.14 ± 164.27, p = 0.063, vs. −62.62 ± 135.160 kcal/day, p = 0.166, respectively). We conclude that non‐ventilated facemask cannot produce comparable metabolic data and should not be used for RMR in place of a ventilated canopy.

Subjects

MeSH terms (MEDLINE)

Basal MetabolismCalorimetry, IndirectMasksHumansMaleFemaleAdultOxygen Consumption

Author keywords

indirect calorimetrymetabolic carttotal daily energy expenditureventilated hood

Authors and institutions

  • Department of Health and Exercise Science, University of Oklahoma, Norman, Oklahoma, USA.
  • Harold Hamm Diabetes Center, University of Oklahoma Health Campus, Oklahoma City, Oklahoma, USA.
  • TSET Health Promotion Research Center, The University of Oklahoma Health Campus, Oklahoma City, Oklahoma, USA.
  • Program for Cellular and Behavioral Neurobiology, University of Oklahoma, Norman, Oklahoma, USA.

ORCID profiles: Yair Pincu

Cite

APA

Pincu, Y., Sakshi, F. N. U., Chesbro, G. A., Falahati, A., & Larson, R. D. (2026). A comparison of resting metabolic rate measurement in adults, using a ventilated canopy or a mixing‐chamber system with a silicone mask. Physiological Reports, 14(6). https://doi.org/10.14814/phy2.70837

Vancouver

Pincu Y, Sakshi FNU, Chesbro GA, Falahati A, Larson RD. A comparison of resting metabolic rate measurement in adults, using a ventilated canopy or a mixing‐chamber system with a silicone mask. Physiological Reports. 2026;14(6). doi:10.14814/phy2.70837

BibTeX
@article{Pincu2026,
  author = {Pincu, Yair and Sakshi, F N U and Chesbro, Grant A and Falahati, Akram and Larson, Rebecca D},
  title = {A comparison of resting metabolic rate measurement in adults, using a ventilated canopy or a mixing‐chamber system with a silicone mask},
  journal = {Physiological Reports},
  year = {2026},
  volume = {14},
  number = {6},
  doi = {10.14814/phy2.70837}
}
Start for free →