Validity and reproducibility of a whole‐room indirect calorimeter for measurement of the thermic effect of food
Physiological Reports · 2026
DOI: 10.14814/phy2.70740 ↗At a glance
Validierungsstudie in Physiological Reports, 2026. Written by Mina Marie Minge and 8 co-authors. Institution: Department of Nutrition, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway. Major MEDLINE topics: Calorimetry, Indirect, Energy Metabolism, Thermogenesis. 53 references. The full text is freely available (open access, CC BY 4.0). Funded by: Direktør Throne Holsts Fond For Ernæringsforskning (Throne-Holst Foundation for Nutrition Research), University of Oslo (UiO), Universitetet i Oslo.
Abstract (original language)
Whole‐room indirect calorimeters (WRICs) measure respiratory exchange, energy expenditure, and macronutrient oxidation. The thermic effect of food (TEF) that occurs after food intake due to digestion, absorption, and storage of nutrients is an important component of daily energy expenditure, but difficult to quantify using metabolic carts. This study evaluated the validity and reproducibility of a 7209 L WRIC for TEF measurement. Technical validation was performed with 7‐h propane combustion tests ( n = 5), and biological reproducibility was tested in 10 healthy subjects (6 men, mean age 33.5 ± 10.3 years) in replicate 7‐h measurements, after a 3‐day run‐in protocol. Coefficient of variation (CV) and intraclass correlation coefficient (ICC) were calculated for ventilation rates of O 2 (VO 2 ) and CO 2 (VCO 2 ), respiratory exchange ratio (RER; VCO 2 /VO 2 ), postprandial energy expenditure, and TEF. Technical validation showed good validity with CVs ranging from 0.23% for RER to 1.74% for energy expenditure. For biological reproducibility, CVs were 3.42%, 1.97%, 2.58%, 3.07%, and 27.48% for VO 2 , VCO 2 , postprandial RER, postprandial energy expenditure, and TEF, respectively. ICCs were excellent for VO 2 (96%), VCO 2 (98%), and postprandial energy expenditure (96%), but poor for TEF (24%). In conclusion, the 7209 L WRIC is technically valid and reproducible for ventilation rates and postprandial energy expenditure but showed lower reproducibility for TEF.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Nutrition, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway.
- Department of Clinical Service, Division of Cancer Medicine, Oslo University Hospital, Oslo, Norway.
- Department of Human Nutrition, Institute of Human Nutrition and Food Sciences, Kiel University, Kiel, Germany.
- D & S Consulting Services Inc, Research and Development, New York, New York, USA.
ORCID profiles: Thomas Olsen
Funding
- Direktør Throne Holsts Fond For Ernæringsforskning (Throne-Holst Foundation for Nutrition Research)
- University of Oslo (UiO)
- Universitetet i Oslo
Cite
APA
Minge, M. M., Henriksen, C., Augestad, E. M. S., Blomhoff, R., Hägele, F. A., Dörner, R., Rising, R., Ulven, S. M., & Olsen, T. (2026). Validity and reproducibility of a whole‐room indirect calorimeter for measurement of the thermic effect of food. Physiological Reports. https://doi.org/10.14814/phy2.70740
Vancouver
Minge MM, Henriksen C, Augestad EMS, Blomhoff R, Hägele FA, Dörner R, et al. Validity and reproducibility of a whole‐room indirect calorimeter for measurement of the thermic effect of food. Physiological Reports. 2026. doi:10.14814/phy2.70740
BibTeX
@article{Minge2026,
author = {Minge, Mina Marie and Henriksen, Christine and Augestad, Elin Maria Sandstad and Blomhoff, Rune and Hägele, Franziska Anna and Dörner, Rebecca and Rising, Russell and Ulven, Stine Marie and Olsen, Thomas},
title = {Validity and reproducibility of a whole‐room indirect calorimeter for measurement of the thermic effect of food},
journal = {Physiological Reports},
year = {2026},
doi = {10.14814/phy2.70740}
}
EUVIMED