EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults

Jack R Dunsford, Jasvir K Dhaliwal, Gracie O Grift, Robert Pryce, Paolo B Dominelli, Yannick Molgat-Seon iD

Physiological Reports · 2024-10 · 12 (19)

DOI: 10.14814/phy2.70068 ↗

At a glance

Journal article in Physiological Reports, published online on 2024-10-02. Written by Jack R Dunsford and 5 co-authors. Institution: Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada. Major MEDLINE topics: Exercise, Exercise Test. Cited 4 times so far (Crossref); 46 references. The full text is freely available (open access, CC BY 4.0). Funded by: Gouvernement du Canada | Natural Sciences and Engineering Research Council of Canada (NSERC), Research Manitoba (RM), Natural Sciences and Engineering Research Council of Canada.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

We sought to determine the repeatability of EFL in healthy adults during incremental cycle exercise. We hypothesized that the repeatability of EFL would be “strong” when assessed as a binary variable (i.e., absent or present) but “poor” when assessed as a continuous variable (i.e., % tidal volume overlap). Thirty‐two healthy adults performed spirometry and an incremental cycle exercise test to exhaustion on two occasions. Standard cardiorespiratory variables were measured at rest and throughout exercise, and EFL was assessed by overlaying tidal expiratory flow‐volume and maximal expiratory flow‐volume curves. The repeatability of EFL was determined using Cohen's κ for binary assessments of EFL and intraclass correlation (ICC) for continuous measures of EFL. During exercise, n = 12 participants (38%) experienced EFL. At peak exercise, the repeatability of EFL was “minimal” ( κ = 0.337, p = 0.145) when assessed as a binary variable and “poor” when measured as a continuous variable (ICC = 0.338, p = 0.025). At matched levels of minute ventilation during high‐intensity exercise (i.e., >75% of peak oxygen uptake), the repeatability of EFL was “weak” when measured as a binary variable ( κ = 0.474, p = 0.001) and “moderate” when measured as a continuous variable (ICC = 0.603, p < 0.001). Our results highlight the day‐to‐day variability associated with assessing EFL during exercise in healthy adults.

Subjects

MeSH terms (MEDLINE)

ExerciseExercise TestHumansMaleFemaleAdultReproducibility of ResultsTidal VolumeSpirometryYoung AdultOxygen Consumption

Author keywords

expiratory flow limitationrepeatabilityventilatory capacityventilatory constraintventilatory demand

Authors and institutions

  • Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada.
  • Department of Kinesiology and Health Sciences, University of Waterloo, Waterloo, Ontario, Canada.
  • Centre for Heart and Lung Innovation, St. Paul's Hospital, Vancouver, British Columbia, Canada.

ORCID profiles: Yannick Molgat-Seon

Funding

  • Gouvernement du Canada | Natural Sciences and Engineering Research Council of Canada (NSERC)
  • Research Manitoba (RM)
  • Natural Sciences and Engineering Research Council of Canada

Cite

APA

Dunsford, J. R., Dhaliwal, J. K., Grift, G. O., Pryce, R., Dominelli, P. B., & Molgat-Seon, Y. (2024). Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults. Physiological Reports, 12(19). https://doi.org/10.14814/phy2.70068

Vancouver

Dunsford JR, Dhaliwal JK, Grift GO, Pryce R, Dominelli PB, Molgat-Seon Y. Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults. Physiological Reports. 2024;12(19). doi:10.14814/phy2.70068

BibTeX
@article{Dunsford2024,
  author = {Dunsford, Jack R and Dhaliwal, Jasvir K and Grift, Gracie O and Pryce, Robert and Dominelli, Paolo B and Molgat-Seon, Yannick},
  title = {Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults},
  journal = {Physiological Reports},
  year = {2024},
  volume = {12},
  number = {19},
  doi = {10.14814/phy2.70068}
}
Start for free →