Breath-by-Breath Measurement of Respiratory Frequency and Tidal Volume with a Multiple-Camera Motion Capture System During Cycling Incremental Exercise
Sensors · 2025
DOI: 10.3390/s25082578 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Carlo Massaroni und 10 weiteren Autor:innen. Beteiligte Einrichtung: Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, 00128 Rome, Italy. Hauptthemen laut MEDLINE: Tidal Volume, Bicycling, Exercise, Respiratory Rate. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study evaluates the performance of a 32-marker motion capture (MoCap) system in estimating respiratory frequency (fR) and tidal volume (VT) during cycling exercise. Fourteen well-trained cyclists performed an incremental step test on a cycle ergometer, while simultaneously recording a raw flow signal with a reference metabolic cart (COSMED) and respiratory-induced torso movements with twelve optoelectronic cameras registering the position of 32 markers affixed to the torso. fR and VT were calculated from both systems on a breath-by-breath basis. The MoCap system showed a strong correlation with the COSMED system when measuring fR and VT (r2 = 0.99, r2 = 0.87, respectively) during exercise. For fR, the mean absolute error (MAE) and mean absolute percentage error (MAPE) were 0.79 breaths/min and 2.1%, respectively. For VT, MoCap consistently underestimated values compared to COSMED, showing a bias (MOD ± LOA) of −0.11 ± 0.42 L and MAPE values of 8%. These findings highlight the system’s capabilities for real-time respiratory monitoring in athletic environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, 00128 Rome, Italy.
- Fondazione Policlinico Campus Bio-Medico di Roma, 00128 Rome, Italy.
- Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", 00135 Rome, Italy.
- Faculdade de Educação Física, Universidade Estadual de Campinas, Campinas 13083-970, Brazil.
- Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy.
- Department of Industrial and Information Engineering, University of Pavia, Via Adolfo Ferrata 5, 27100 Pavia, Italy.
ORCID-Profile: Carlo Massaroni, Andrea Nicolò, Chiara Romano, Mariangela Pinnelli, Emiliano Schena, Pietro Cerveri, Massimo Sacchetti, Sergio Silvestri
Zitieren
APA
Massaroni, C., Nicolò, A., Lopes, A. L. C., Romano, C., Pinnelli, M., Sarro, K., Schena, E., Cerveri, P., Sacchetti, M., Silvestri, S., & Silvatti, A. P. (2025). Breath-by-Breath Measurement of Respiratory Frequency and Tidal Volume with a Multiple-Camera Motion Capture System During Cycling Incremental Exercise. Sensors. https://doi.org/10.3390/s25082578
Vancouver
Massaroni C, Nicolò A, Lopes ALC, Romano C, Pinnelli M, Sarro K, et al. Breath-by-Breath Measurement of Respiratory Frequency and Tidal Volume with a Multiple-Camera Motion Capture System During Cycling Incremental Exercise. Sensors. 2025. doi:10.3390/s25082578
BibTeX
@article{Massaroni2025,
author = {Massaroni, Carlo and Nicolò, Andrea and Lopes, Ana Luiza de Castro and Romano, Chiara and Pinnelli, Mariangela and Sarro, Karine and Schena, Emiliano and Cerveri, Pietro and Sacchetti, Massimo and Silvestri, Sergio and Silvatti, Amanda Piaia},
title = {Breath-by-Breath Measurement of Respiratory Frequency and Tidal Volume with a Multiple-Camera Motion Capture System During Cycling Incremental Exercise},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25082578}
}
EUVIMED