Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults
Physiological Reports · 2024-10 · 12 (19)
DOI: 10.14814/phy2.70068 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Reports, online erschienen am 02.10.2024. Verfasst von Jack R Dunsford und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada. Hauptthemen laut MEDLINE: Exercise, Exercise Test. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gouvernement du Canada | Natural Sciences and Engineering Research Council of Canada (NSERC), Research Manitoba (RM), Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
We sought to determine the repeatability of EFL in healthy adults during incremental cycle exercise. We hypothesized that the repeatability of EFL would be “strong” when assessed as a binary variable (i.e., absent or present) but “poor” when assessed as a continuous variable (i.e., % tidal volume overlap). Thirty‐two healthy adults performed spirometry and an incremental cycle exercise test to exhaustion on two occasions. Standard cardiorespiratory variables were measured at rest and throughout exercise, and EFL was assessed by overlaying tidal expiratory flow‐volume and maximal expiratory flow‐volume curves. The repeatability of EFL was determined using Cohen's κ for binary assessments of EFL and intraclass correlation (ICC) for continuous measures of EFL. During exercise, n = 12 participants (38%) experienced EFL. At peak exercise, the repeatability of EFL was “minimal” ( κ = 0.337, p = 0.145) when assessed as a binary variable and “poor” when measured as a continuous variable (ICC = 0.338, p = 0.025). At matched levels of minute ventilation during high‐intensity exercise (i.e., >75% of peak oxygen uptake), the repeatability of EFL was “weak” when measured as a binary variable ( κ = 0.474, p = 0.001) and “moderate” when measured as a continuous variable (ICC = 0.603, p < 0.001). Our results highlight the day‐to‐day variability associated with assessing EFL during exercise in healthy adults.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Kinesiology and Applied Health, University of Winnipeg, Winnipeg, Manitoba, Canada.
- Department of Kinesiology and Health Sciences, University of Waterloo, Waterloo, Ontario, Canada.
- Centre for Heart and Lung Innovation, St. Paul's Hospital, Vancouver, British Columbia, Canada.
ORCID-Profile: Yannick Molgat-Seon
Förderung
- Gouvernement du Canada | Natural Sciences and Engineering Research Council of Canada (NSERC)
- Research Manitoba (RM)
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Dunsford, J. R., Dhaliwal, J. K., Grift, G. O., Pryce, R., Dominelli, P. B., & Molgat-Seon, Y. (2024). Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults. Physiological Reports, 12(19). https://doi.org/10.14814/phy2.70068
Vancouver
Dunsford JR, Dhaliwal JK, Grift GO, Pryce R, Dominelli PB, Molgat-Seon Y. Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults. Physiological Reports. 2024;12(19). doi:10.14814/phy2.70068
BibTeX
@article{Dunsford2024,
author = {Dunsford, Jack R and Dhaliwal, Jasvir K and Grift, Gracie O and Pryce, Robert and Dominelli, Paolo B and Molgat-Seon, Yannick},
title = {Assessing the repeatability of expiratory flow limitation during incremental exercise in healthy adults},
journal = {Physiological Reports},
year = {2024},
volume = {12},
number = {19},
doi = {10.14814/phy2.70068}
}
EUVIMED