EUVIMEDObjevte EUVIMED
VergleichsstudieOpen access · CC BY 4.0

Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation

Riccardo G Sorrentino, Edwin Avila-Mirèles, Jan Babič iD, Matej Supej, Igor B Mekjavic iD, Adam C McDonnell

Physiological Reports · 2024-07 · 12 (13)

DOI: 10.14814/phy2.16034 ↗

At a glance

Vergleichsstudie in Physiological Reports, 2024-07. Written by Riccardo G Sorrentino and 5 co-authors. Institution: Department of Automatics, Biocybernetics and Robotics, Jožef Stefan Institute, Ljubljana, Slovenia. Major MEDLINE topics: Range of Motion, Articular, Centrifugation, Knee Joint, Exercise. Cited 4 times so far (Crossref); 36 references. The full text is freely available (open access, CC BY 4.0). Funded by: Slovenian Research and Innovation Agency (ARiS Programme.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

This study compared the joint kinematics between the front squat (FS) conducted in the upright (natural gravity) position and in the supine position on a short arm human centrifuge (SAHC). Male participants ( N = 12) with no prior experience exercising on a centrifuge completed a FS in the upright position before (PRE) and after (POST) a FS exercise conducted on the SAHC while exposed to artificial gravity (AG). Participants completed, in randomized order, three sets of six repetitions with a load equal to body weight or 1.25 × body weight for upright squats, and 1 g and 1.25 g at the center of gravity (COG) for AG. During the terrestrial squats, the load was applied with a barbell. Knee (left/right) and hip (left/right) flexion angles were recorded with a set of inertial measurement units. AG decreased the maximum flexion angle (MAX) of knees and hips as well as the range of motion (ROM), both at 1 and 1.25 g. Minor adaptation was observed between the first and the last repetition performed in AG. AG affects the ability to FS in naïve participants by reducing MAX, MIN and ROM of the knees and hip.

Subjects

MeSH terms (MEDLINE)

Range of Motion, ArticularCentrifugationKnee JointExerciseHumansMaleBiomechanical PhenomenaAdultYoung AdultHip JointPostureGravity, Altered

Author keywords

artificial gravityhuman centrifugationmotion analysismovement adaptationsquat kinematic

Authors and institutions

  • Department of Automatics, Biocybernetics and Robotics, Jožef Stefan Institute, Ljubljana, Slovenia.
  • Jožef Stefan International Postgraduate School, Ljubljana, Slovenia.
  • Universal Robots, Research and Development Department, Odense, Denmark.
  • Faculty of Sport, University of Ljubljana, Ljubljana, Slovenia.

ORCID profiles: Jan Babič, Igor B Mekjavic

Funding

  • Slovenian Research and Innovation Agency (ARiS Programme

Cite

APA

Sorrentino, R. G., Avila-Mirèles, E., Babič, J., Supej, M., Mekjavic, I. B., & McDonnell, A. C. (2024). Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation. Physiological Reports, 12(13). https://doi.org/10.14814/phy2.16034

Vancouver

Sorrentino RG, Avila-Mirèles E, Babič J, Supej M, Mekjavic IB, McDonnell AC. Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation. Physiological Reports. 2024;12(13). doi:10.14814/phy2.16034

BibTeX
@article{Sorrentino2024,
  author = {Sorrentino, Riccardo G and Avila-Mirèles, Edwin and Babič, Jan and Supej, Matej and Mekjavic, Igor B and McDonnell, Adam C},
  title = {Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation},
  journal = {Physiological Reports},
  year = {2024},
  volume = {12},
  number = {13},
  doi = {10.14814/phy2.16034}
}
Start for free →