The Influence of Knee Position on Ultrasound Imaging of Femoral Cartilage in Individuals with Anterior Cruciate Ligament Reconstruction
CARTILAGE · 2024
DOI: 10.1177/19476035231205682 ↗Kurz gefasst
Fachartikel in der Zeitschrift CARTILAGE, 2024. Verfasst von Harry S Battersby und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Kinesiology, Western University, London, ON, Canada. Hauptthemen laut MEDLINE: Anterior Cruciate Ligament Reconstruction, Cartilage, Articular, Ultrasonography, Knee Joint. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: program for education and research in biotechnology, california state university.
Abstract (Originalsprache)
Background
Articular cartilage is important for knee function and can be imaged using ultrasound. The purpose was to compare femoral cartilage thickness and echo intensity (EI) measured at 90° and 140° of knee flexion and between limbs in a cohort with unilateral anterior cruciate ligament reconstruction (ACLR). We also examined associations between gait biomechanics and cartilage outcomes.
Methods
Twenty-seven individuals with primary unilateral ACLR participated (12 men, 15 women; age = 22.3 ± 3.8 years; time since ACLR = 71.2 ± 47.2 months). Ultrasound was used to obtain femoral cartilage measurements. Gait outcomes included peak KFA (knee flexion angle) and peak external knee flexion moment (KFM). Cartilage outcomes were compared using a 2 ( position ) × 2 ( limb ) repeated measures ANOVA (analysis of variance). Gait and cartilage associations were assessed using linear regression.
Findings
There were no position × limb interactions for any cartilage outcome (all P > 0.05). Medial ( P = 0.038) and central cartilage ( P < 0.001) were thicker, whereas central ( P = 0.029) and lateral cartilage EI ( P = 0.003) were lower when measured at 90° than those at 140° of knee flexion. Medial cartilage was thicker in the ACLR than that in the contralateral limb ( P = 0.016). A larger KFM was associated with thicker medial cartilage (ΔR 2 = 0.146, P = 0.021) and central cartilage (ΔR 2 = 0.159, P = 0.039) measured at 140° of knee flexion in the ACLR limb but not at 90°.
Interpretation
Findings suggest that imaging position influences cartilage thickness and EI measurements in individuals with ACLR and should be considered in study designs and clinical evaluation. A greater KFM was associated with thicker cartilage within specific portions of the distal femur.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Kinesiology, Western University, London, ON, Canada.
- Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA, USA.
- Department of Kinesiology, University of Georgia, Athens, GA, USA.
- Nashville Soccer Club, Nashville, TN, USA.
- School of Kinesiology, University of Michigan, Ann Arbor, MI, USA.
ORCID-Profile: Harry S Battersby, Skylar C Holmes, Derek N Pamukoff
Förderung
- program for education and research in biotechnology, california state university
Zitieren
APA
Battersby, H. S., Holmes, S. C., Shumski, E. J., Heredia, C. E., Garcia, S. A., & Pamukoff, D. N. (2024). The Influence of Knee Position on Ultrasound Imaging of Femoral Cartilage in Individuals with Anterior Cruciate Ligament Reconstruction. CARTILAGE. https://doi.org/10.1177/19476035231205682
Vancouver
Battersby HS, Holmes SC, Shumski EJ, Heredia CE, Garcia SA, Pamukoff DN. The Influence of Knee Position on Ultrasound Imaging of Femoral Cartilage in Individuals with Anterior Cruciate Ligament Reconstruction. CARTILAGE. 2024. doi:10.1177/19476035231205682
BibTeX
@article{Battersby2024,
author = {Battersby, Harry S and Holmes, Skylar C and Shumski, Eric J and Heredia, Caitlyn E and Garcia, Steven A and Pamukoff, Derek N},
title = {The Influence of Knee Position on Ultrasound Imaging of Femoral Cartilage in Individuals with Anterior Cruciate Ligament Reconstruction},
journal = {CARTILAGE},
year = {2024},
doi = {10.1177/19476035231205682}
}
EUVIMED