EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation

Riccardo G Sorrentino, Edwin Avila-Mirèles, Jan Babič iD, Matej Supej, Igor B Mekjavic iD, Adam C McDonnell

Physiological Reports · 2024-07 · 12 (13)

DOI: 10.14814/phy2.16034 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Physiological Reports, 2024-07. Verfasst von Riccardo G Sorrentino und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Automatics, Biocybernetics and Robotics, Jožef Stefan Institute, Ljubljana, Slovenia. Hauptthemen laut MEDLINE: Range of Motion, Articular, Centrifugation, Knee Joint, Exercise. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Slovenian Research and Innovation Agency (ARiS Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study compared the joint kinematics between the front squat (FS) conducted in the upright (natural gravity) position and in the supine position on a short arm human centrifuge (SAHC). Male participants ( N = 12) with no prior experience exercising on a centrifuge completed a FS in the upright position before (PRE) and after (POST) a FS exercise conducted on the SAHC while exposed to artificial gravity (AG). Participants completed, in randomized order, three sets of six repetitions with a load equal to body weight or 1.25 × body weight for upright squats, and 1 g and 1.25 g at the center of gravity (COG) for AG. During the terrestrial squats, the load was applied with a barbell. Knee (left/right) and hip (left/right) flexion angles were recorded with a set of inertial measurement units. AG decreased the maximum flexion angle (MAX) of knees and hips as well as the range of motion (ROM), both at 1 and 1.25 g. Minor adaptation was observed between the first and the last repetition performed in AG. AG affects the ability to FS in naïve participants by reducing MAX, MIN and ROM of the knees and hip.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Range of Motion, ArticularCentrifugationKnee JointExerciseHumansMaleBiomechanical PhenomenaAdultYoung AdultHip JointPostureGravity, Altered

Stichwörter der Autor:innen

artificial gravityhuman centrifugationmotion analysismovement adaptationsquat kinematic

Autor:innen und Institutionen

  • Department of Automatics, Biocybernetics and Robotics, Jožef Stefan Institute, Ljubljana, Slovenia.
  • Jožef Stefan International Postgraduate School, Ljubljana, Slovenia.
  • Universal Robots, Research and Development Department, Odense, Denmark.
  • Faculty of Sport, University of Ljubljana, Ljubljana, Slovenia.

ORCID-Profile: Jan Babič, Igor B Mekjavic

Förderung

  • Slovenian Research and Innovation Agency (ARiS Programme

Zitieren

APA

Sorrentino, R. G., Avila-Mirèles, E., Babič, J., Supej, M., Mekjavic, I. B., & McDonnell, A. C. (2024). Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation. Physiological Reports, 12(13). https://doi.org/10.14814/phy2.16034

Vancouver

Sorrentino RG, Avila-Mirèles E, Babič J, Supej M, Mekjavic IB, McDonnell AC. Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation. Physiological Reports. 2024;12(13). doi:10.14814/phy2.16034

BibTeX
@article{Sorrentino2024,
  author = {Sorrentino, Riccardo G and Avila-Mirèles, Edwin and Babič, Jan and Supej, Matej and Mekjavic, Igor B and McDonnell, Adam C},
  title = {Comparison of joint kinematics between upright front squat exercise and horizontal squat exercise performed on a short arm human centrifugation},
  journal = {Physiological Reports},
  year = {2024},
  volume = {12},
  number = {13},
  doi = {10.14814/phy2.16034}
}
Kostenlos starten →