Kurz gefasst

Fachartikel in der Zeitschrift Physiological Reports, 2023. Verfasst von Philip J Peyton. Beteiligte Einrichtung: Department of Critical Care, Anaesthesia, Perioperative and Pain Medicine Program, Melbourne Medical School, University of Melbourne, Melbourne, Vict…. Hauptthemen laut MEDLINE: Carbon Dioxide, Oxygen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian and New Zealand College of Anaesthetists.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the three‐compartment model of lung ventilation‐perfusion heterogeneity (VA/Q scatter), both Bohr dead space and shunt equations require values for central “ideal” compartment O 2 and CO 2 partial pressures. However, the ideal alveolar gas equation most accurately calculates mixed (ideal and alveolar dead space) PAO 2 . A novel “modal” definition has been validated for ideal alveolar CO 2 partial pressure, at the VA/Q ratio in a lung distribution where CO 2 elimination is maximal. A multicompartment computer model of physiological, lognormal distributions of VA and Q was used to identify modal “ideal” PAO 2 , and find a modification of the alveolar gas equation to estimate it across a wide range of severity of VA/Q heterogeneity and FIO 2 . This was then validated in vivo using data from a study of 36 anesthetized, ventilated patients with FIO 2 0.35–80. Substitution in the alveolar gas equation of respiratory exchange ratio R with achieved excellent agreement ( r 2 = 0.999) between the calculated ideal PAO 2 and the alveolar‐capillary Pc'O 2 at the modal VO 2 point (“modal” Pc'O 2 ), across a range of log standard deviation of VA 0.25–1.75, true shunt 0%–20%, overall VA/Q 0.4–1.6, and FIO 2 0.18–1.0, where the modeled PaO 2 was over 50 mm Hg. Modal ideal PAO 2 can be reliably estimated using routine blood gas measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon DioxideOxygenHumansBlood Gas AnalysisComputer SimulationPartial Pressure

Substanzen

Carbon DioxideOxygen

Autor:innen und Institutionen

  • Department of Critical Care, Anaesthesia, Perioperative and Pain Medicine Program, Melbourne Medical School, University of Melbourne, Melbourne, Victoria, Australia.
  • Department of Anaesthesia, Austin Health, Melbourne, Victoria, Australia.
  • Institute for Breathing and Sleep, Melbourne, Victoria, Australia.

ORCID-Profile: Philip J Peyton

Förderung

  • Australian and New Zealand College of Anaesthetists

Zitieren

APA

Peyton, P. J. (2023). A modal definition of ideal alveolar oxygen. Physiological Reports. https://doi.org/10.14814/phy2.15787

Vancouver

Peyton PJ. A modal definition of ideal alveolar oxygen. Physiological Reports. 2023. doi:10.14814/phy2.15787

BibTeX
@article{Peyton2023,
  author = {Peyton, Philip J},
  title = {A modal definition of ideal alveolar oxygen},
  journal = {Physiological Reports},
  year = {2023},
  doi = {10.14814/phy2.15787}
}
Kostenlos starten →