EUVIMEDEUVIMED entdecken
Crossref

Determination of PAO2 by the “ideal” alveolar gas concept and by miget in ventilated animals

Gerardo Tusman, Stephan H Böhm, Fernando Suarez-Sipmann

Respiratory Physiology & Neurobiology · 2025

DOI: 10.1016/j.resp.2025.104474 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Respiratory Physiology & Neurobiology, 2025. Verfasst von Gerardo Tusman und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Hospital Privado de Comunidad, Mar del Plata, Argentina. Electronic address: gtusman@hotmail.com. Hauptthemen laut MEDLINE: Pulmonary Alveoli, Oxygen, Carbon Dioxide, Pulmonary Gas Exchange. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Ideal Alveolar Gas Concept calculates the alveolar partial pressure of oxygen (PAO2) using arterial (PaCO2) instead of alveolar (PACO2) partial pressures of carbon dioxide in the alveolar gas equation. We compared the effects of shunt on PAO2 calculated by the "ideal" gas concept with a calculation using the multiple inert gas elimination technique (MIGET). We tested the hypothesis that shunt affects PACO2 and introduces significant errors in the estimation of PAO2 in two experimental porcine models. First, in a lung-lavage model (n = 10), shunt changes were induced by applying different levels of positive end-expiratory pressure. PaCO2 median 71 mmHg, (IQR 21 mmHg) was higher than MIGET PACO2 52(20) mmHg (p < 0.001). Ideal PAO2 654(33) mmHg was lower than MIGET PAO2 670(19) mmHg (p < 0.001). Bias in PAO2 was -23 mmHg with limits of agreement between 19 to -65 mmHg. Second, in a one-lung ventilation model (n = 10), changes in shunt were performed decreasing cardiac output by inferior vena cava balloon inflations (OLVCB), inhibiting hypoxic pulmonary constriction with nitroprusiate (OLVNPS) and increasing cardiac output with dobutamine (OLVDBT). Baseline PaCO2 was 55(10) mmHg and shunt 9(19)%. Cardiac output reduction did not affect PaCO2 57(9) mmHg (p = 0.19) or shunt 9(15)% (p = 0.570). Inhibiting hypoxic pulmonary vasoconstriction increased PaCO2 [62(13) mmHg; p = 0.083] and shunt [26(20)%; p = 0.020]. Cardiac output increase resulted in higher PaCO2 [67(11) mmHg; p = 0.004] and shunt [30(29)%; p = 0.012]. The assumption of the ideal gas concept that PaCO2 is not affected by shunt is incorrect introducing significant estimation errors in the alveolar gas equation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary AlveoliOxygenCarbon DioxidePulmonary Gas ExchangeAnimalsSwinePartial PressurePositive-Pressure RespirationBlood Gas Analysis

Stichwörter der Autor:innen

Alveolar gasCarbon dioxideIdeal Alveolar Gas ConceptOxygenPAO(2)Shunt

Substanzen

OxygenCarbon Dioxide

Autor:innen und Institutionen

  • Department of Anesthesiology, Hospital Privado de Comunidad, Mar del Plata, Argentina. Electronic address: gtusman@hotmail.com.
  • Department of Anesthesiology and Intensive Care Medicine, Rostock University Medical Center, Rostock, Germany.
  • CIBERES, Madrid, Spain; Department of Critical Care, Hospital Universitario de La Princesa, Universidad Autonoma de Madrid, Instituto de investigación Sanitaria La Princesa, Madrid, Spain.

Zitieren

APA

Tusman, G., Böhm, S. H., & Suarez-Sipmann, F. (2025). Determination of PAO2 by the “ideal” alveolar gas concept and by miget in ventilated animals. Respiratory Physiology & Neurobiology. https://doi.org/10.1016/j.resp.2025.104474

Vancouver

Tusman G, Böhm SH, Suarez-Sipmann F. Determination of PAO2 by the “ideal” alveolar gas concept and by miget in ventilated animals. Respiratory Physiology & Neurobiology. 2025. doi:10.1016/j.resp.2025.104474

BibTeX
@article{Tusman2025,
  author = {Tusman, Gerardo and Böhm, Stephan H and Suarez-Sipmann, Fernando},
  title = {Determination of PAO2 by the “ideal” alveolar gas concept and by miget in ventilated animals},
  journal = {Respiratory Physiology & Neurobiology},
  year = {2025},
  doi = {10.1016/j.resp.2025.104474}
}
Kostenlos starten →