Comparison of intra-abdominal adhesions formation following implantation of synthetic, biosynthetic, and biologic meshes in a rat model
Turkish Journal of Trauma and Emergency Surgery · 2026
DOI: 10.14744/tjtes.2026.87933 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Turkish Journal of Trauma and Emergency Surgery, 2026. Verfasst von Şeref Oray und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Surgery, Başakşehir Çam and Sakura City Hospital, İstanbul-Türkiye. Hauptthemen laut MEDLINE: Surgical Mesh. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Intra-abdominal adhesions remain a significant challenge in incisional hernia repair, often resulting in complications such as bowel obstruction and chronic pain. Although various prosthetic meshes have been developed, their comparative adhesion profiles have not been fully elucidated. This experimental study aimed to compare the severity of intra-abdominal adhesions and the associated histopathological responses induced by synthetic, biosynthetic, biological, and chemically treated meshes in a standardized rat model. METHODS: Fifty Wistar albino rats were randomly assigned to five groups (n=10 each): control, polypropylene mesh (Prolene®), polypropylene mesh impregnated with tissue adhesive (Tisseel®), dual mesh (Gore® DualMesh®), and biological mesh (Permacol®). A standardized 2×2 cm full-thickness abdominal wall defect was created in each animal, followed by intraperitoneal mesh implantation. On post-operative day 30, macroscopic adhesions were assessed using the Modified Diamond Scale. Histopathological evaluation included grading of fibrosis, inflammation, vascular proliferation, and giant cell reaction. Statistical analysis was performed using the Kruskal-Wallis test and post hoc multiple comparison analyses. RESULTS: The Prolene mesh group demonstrated the highest adhesion severity (mean Modified Diamond score: 2.80±1.23), which was significantly greater than that observed in the biological mesh (p=0.010), dual mesh (p=0.002), and tissue adhesive-impregnated Prolene groups (p=0.033). Fibrosis and inflammation were also most pronounced in the Prolene and dual mesh groups, whereas the biological mesh group exhibited milder responses (fibrosis p=0.028; inflammation p=0.033 compared to Prolene). Vascular proliferation and giant cell counts were significantly lower in the biological mesh group (p=0.004 and p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of General Surgery, Başakşehir Çam and Sakura City Hospital, İstanbul-Türkiye.
- Department of General Surgery, Ankara University Faculty of Medicine, Ankara-Türkiye.
Zitieren
APA
Oray, Ş., & Çakmak, A. (2026). Comparison of intra-abdominal adhesions formation following implantation of synthetic, biosynthetic, and biologic meshes in a rat model. Turkish Journal of Trauma and Emergency Surgery. https://doi.org/10.14744/tjtes.2026.87933
Vancouver
Oray Ş, Çakmak A. Comparison of intra-abdominal adhesions formation following implantation of synthetic, biosynthetic, and biologic meshes in a rat model. Turkish Journal of Trauma and Emergency Surgery. 2026. doi:10.14744/tjtes.2026.87933
BibTeX
@article{Oray2026,
author = {Oray, Şeref and Çakmak, Atıl},
title = {Comparison of intra-abdominal adhesions formation following implantation of synthetic, biosynthetic, and biologic meshes in a rat model},
journal = {Turkish Journal of Trauma and Emergency Surgery},
year = {2026},
doi = {10.14744/tjtes.2026.87933}
}
EUVIMED