EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intraperitoneal Polypropylene Mesh in Clean, Potentially Septic, and Controlled Contamination Fields: An Experimental Rat Study

Apostolos Makrantonakis, Ioannis Mantzoros, Orestis Ioannidis iD, Konstantinos Zapsalis, Elissavet Anestiadou iD, Styliani Parpoudi, Dimitrios Kyziridis iD, Ekaterini Klonou, Savvas Simeonidis, Stefanos Bitsianis iD, Manousos George Pramateftakis, Efstathios Kotidis und 1 weitere

Medicina · 2026

DOI: 10.3390/medicina62050803 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medicina, 2026. Verfasst von Apostolos Makrantonakis und 12 weiteren Autor:innen. Beteiligte Einrichtung: 4th Surgical Clinic, School of Medicine, Faculty of Health Science, Aristotle University of Thessaloniki, 541 24 Thessaloniki, Greece. Hauptthemen laut MEDLINE: Surgical Mesh, Polypropylenes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Intraperitoneal onlay mesh (IPOM) reduces ventral/incisional hernia recurrence but raises concern for adhesions and infection, particularly when the operative field is not strictly clean. We aimed to determine how contamination severity modulates the peritoneal response to intraperitoneal polypropylene mesh. Materials and Methods: In a prospective, randomized, blinded rat study, 60 male Wistar rats were allocated to three groups (n = 20/group) and evaluated at postoperative day (POD) 4 and POD 8 (n = 10/timepoint): A, clean mesh placement; B, small-bowel resection with end-to-end anastomosis without spillage (“potentially septic”); and C, mesh placement followed by intraperitoneal inoculation with Escherichia coli and Staphylococcus aureus (“controlled contamination”). The primary outcome was adhesion severity (Van der Ham scale, 0–3). Secondary outcomes included semi-quantitative histological scores (0–4) for neutrophil infiltration, fibroblast proliferation, neoangiogenesis, and collagen deposition. Prespecified non-parametric analyses were applied.

Results

All animals completed follow-up; no pre-sacrifice deaths occurred. Adhesion severity showed no statistically significant differences between Groups A and B at either timepoint (mean POD4: 0.3 vs. 0.6; POD8: 0.4 vs. 0.8; p > 0.05). In contrast, Group C demonstrated markedly higher adhesion scores (mean POD4: 2.3; POD8: 2.4; both p < 0.001 vs. Groups A and B), with a substantially greater proportion of grade 2–3 adhesions. Histological parameters paralleled these findings: at both POD4 and POD8, Group C showed significantly higher neutrophil, fibroblast, neoangiogenesis, and collagen scores compared with Groups A and B (all p < 0.001). No statistically significant within-group temporal differences were observed between POD4 and POD8.

Conclusions

In this experimental model, intraperitoneal polypropylene mesh demonstrated similar early biological response patterns in clean and controlled contamination settings, whereas established intra-abdominal sepsis was associated with a marked escalation of inflammation, fibroproliferation, and adhesion formation. These findings suggest that selective use of synthetic intraperitoneal mesh may be considered when contamination is controlled, while caution is warranted in frankly septic environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgical MeshPolypropylenesAnimalsRatsRats, WistarMaleTissue AdhesionsProspective StudiesRandom AllocationDisease Models, Animal

Stichwörter der Autor:innen

adhesionsanastomosiscontaminated surgical fieldintraperitoneal meshpolypropylenerat modelsepsisventral/incisional hernia repair

Substanzen

Polypropylenes

Autor:innen und Institutionen

  • 4th Surgical Clinic, School of Medicine, Faculty of Health Science, Aristotle University of Thessaloniki, 541 24 Thessaloniki, Greece.

ORCID-Profile: Orestis Ioannidis, Elissavet Anestiadou, Dimitrios Kyziridis, Stefanos Bitsianis

Zitieren

APA

Makrantonakis, A., Mantzoros, I., Ioannidis, O., Zapsalis, K., Anestiadou, E., Parpoudi, S., Kyziridis, D., Klonou, E., Simeonidis, S., Bitsianis, S., Pramateftakis, M. G., Kotidis, E., & Angelopoulos, S. (2026). Intraperitoneal Polypropylene Mesh in Clean, Potentially Septic, and Controlled Contamination Fields: An Experimental Rat Study. Medicina. https://doi.org/10.3390/medicina62050803

Vancouver

Makrantonakis A, Mantzoros I, Ioannidis O, Zapsalis K, Anestiadou E, Parpoudi S, et al. Intraperitoneal Polypropylene Mesh in Clean, Potentially Septic, and Controlled Contamination Fields: An Experimental Rat Study. Medicina. 2026. doi:10.3390/medicina62050803

BibTeX
@article{Makrantonakis2026,
  author = {Makrantonakis, Apostolos and Mantzoros, Ioannis and Ioannidis, Orestis and Zapsalis, Konstantinos and Anestiadou, Elissavet and Parpoudi, Styliani and Kyziridis, Dimitrios and Klonou, Ekaterini and Simeonidis, Savvas and Bitsianis, Stefanos and Pramateftakis, Manousos George and Kotidis, Efstathios and Angelopoulos, Stamatios},
  title = {Intraperitoneal Polypropylene Mesh in Clean, Potentially Septic, and Controlled Contamination Fields: An Experimental Rat Study},
  journal = {Medicina},
  year = {2026},
  doi = {10.3390/medicina62050803}
}
Kostenlos starten →