EUVIMEDEUVIMED entdecken
Vergleichsstudie

Self-gripping versus polypropylene mesh for incisional hernia repair in a rat model

Dianchen Wang iD, Tengfei Shang, Yaohua Zhu, Yang Fu

Surgical Endoscopy · 2025

DOI: 10.1007/s00464-025-11552-4 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Surgical Endoscopy, 2025. Verfasst von Dianchen Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hernia and Abdominal Wall Surgery, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe Road, Zhengzhou, 450052, Henan, …. Hauptthemen laut MEDLINE: Surgical Mesh, Polypropylenes, Incisional Hernia, Herniorrhaphy. Die Arbeit nennt 18 Literaturangaben. Gefördert von: Key Scientific Research Projects of Colleges and Universities in Henan Province in 2022, Special Fund for Clinical Research of Wu Jieping Medical Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Self-gripping mesh, made of monofilament polypropylene and covered by a layer of polylactic acid micro-hooks, is applied in ventral hernia repair, whereas cytological change and collagen expression around the mesh are rarely reported. The objective of this research was to compare inflammatory response and collagen proliferation between self-gripping and polypropylene mesh in rat model of incisional hernia. METHODS: Forty-five rats were randomly divided into unrepaired (UR) group, polypropylene (PP) mesh group, and self-gripping (SG) mesh group and euthanized at 1, 2 and 4 weeks postoperatively. The levels of inflammation, neovascularization, and collagen expression were measured by immunohistochemistry, quantitative real-time polymerase chain reaction, and Western blot. RESULTS: One rat died and others developed typical incisional hernia in UR group, and hematoma, seroma, or wound infection were not observed in PP and SG groups. There was no significant difference in mesh shrinkage and inflammatory infiltration between PP and SG groups. With regard to neovascularization, 2 groups were comparable at 1 and 2 weeks, while the neovascularization score of PP group was statistically higher than that of SG group at 4 weeks. One week after surgery, the amounts of Collagen I (Col I) mRNA in PP group were significantly higher than SG group, while the amounts of Collagen III (Col III) mRNA were comparable between 2 groups. Two weeks following operation, the expressions of Col I mRNA and Col III mRNA in PP group were statistically lower than those in SG group. Four weeks postoperatively, the levels of Col I mRNA and Col III mRNA in PP group were significantly higher than those in SG group. CONCLUSION: Self-gripping mesh induced comparable inflammatory response and collagen proliferation compared with polypropylene mesh in a rat model. REGISTRATION NUMBER: ZZU-LAC2023080121.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgical MeshPolypropylenesIncisional HerniaHerniorrhaphyHernia, VentralAnimalsRatsRats, Sprague-DawleyMaleDisease Models, AnimalRandom AllocationCollagenCollagen Type ICollagen Type III

Stichwörter der Autor:innen

CollagenIncisional herniaPolypropylene meshSelf-gripping mesh

Substanzen

PolypropylenesCollagenCollagen Type ICollagen Type III

Autor:innen und Institutionen

  • Department of Hernia and Abdominal Wall Surgery, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe Road, Zhengzhou, 450052, Henan, China. wdc8681949@163.com.
  • Department of Hernia and Abdominal Wall Surgery, The First Affiliated Hospital of Zhengzhou University, No.1 Jianshe Road, Zhengzhou, 450052, Henan, China.

ORCID-Profile: Dianchen Wang

Förderung

  • Key Scientific Research Projects of Colleges and Universities in Henan Province in 2022
  • Special Fund for Clinical Research of Wu Jieping Medical Foundation

Zitieren

APA

Wang, D., Shang, T., Zhu, Y., & Fu, Y. (2025). Self-gripping versus polypropylene mesh for incisional hernia repair in a rat model. Surgical Endoscopy. https://doi.org/10.1007/s00464-025-11552-4

Vancouver

Wang D, Shang T, Zhu Y, Fu Y. Self-gripping versus polypropylene mesh for incisional hernia repair in a rat model. Surgical Endoscopy. 2025. doi:10.1007/s00464-025-11552-4

BibTeX
@article{Wang2025,
  author = {Wang, Dianchen and Shang, Tengfei and Zhu, Yaohua and Fu, Yang},
  title = {Self-gripping versus polypropylene mesh for incisional hernia repair in a rat model},
  journal = {Surgical Endoscopy},
  year = {2025},
  doi = {10.1007/s00464-025-11552-4}
}
Kostenlos starten →