Short‐ to Mid‐Term Efficacy and Safety of Left Bundle Branch Pacing Guided by Continuous Uninterrupted Paced Intracardiac Electrogram Monitoring Targeting Transition to Selective Left Bundle Branch Capture
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.70054 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Hao Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Ningbo No. 2 Hospital, Ningbo, Zhejiang, China. Hauptthemen laut MEDLINE: Cardiac Pacing, Artificial, Bundle of His, Action Potentials, Heart Rate. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: This work was supported by the Ningbo Major Research and Development Plan Project [Grant Number 2024Z235], Medical Scientific Research Foundation of Zhejiang P….
Abstract (Originalsprache)
Background
Uninterrupted left bundle branch pacing (LBBP) lead implantation with the endpoint of transition to selected (S)‐left bundle (LB) capture is feasible and safe during the procedure; however, the relatively long‐term outcomes remain unknown.
Objective
The present study aimed to evaluate the short‐ to mid‐term performance and safety of uninterrupted LBBP lead implantation.
Methods
Patients who underwent successful LBBP and achieved the implantation endpoint, guided by continuous paced intracardiac electrogram monitoring, were enrolled. Electrocardiograms, pacing parameters, echocardiographic measurements, and complications associated with LBBP were assessed during follow‐up.
Results
A total of 83 patients were enrolled in the study. The mean follow‐up duration was 14.2 ± 8.8 months. Pacing parameters, including R‐wave amplitude, pacing threshold, and impedance, remained stable throughout the follow‐up period for both unipolar and bipolar configurations. The transition from nonselected (NS)‐LB to S‐LB was observed at various unipolar pacing outputs during follow‐up, along with double transitions in bipolar pacing. The proportion of patients transitioning to NS‐LB, S‐LB, and left ventricular septum (LVS) under unipolar pacing at 8 V, 3 V, 2 V, and 1 V remained stable during follow‐up. Left ventricular ejection fraction (62.7 ± 7.0% vs 62.1 ± 11.9%, p = 0.723) remained stable during follow‐up compared to baseline. Left ventricular end‐diastolic dimension (47.5 ± 5.6 mm vs. 51.1 ± 7.1 mm, p = 0.001) decreased significantly.
Conclusions
Uninterrupted LBBP lead implantation with the endpoint of transition to S‐LB, was safe and feasible in short‐ to mid‐term observations. It can improve LVEF in patients with HFrEF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Ningbo No. 2 Hospital, Ningbo, Zhejiang, China.
- Cardiovascular Disease Clinical Medical Research Center of Ningbo, Ningbo, Zhejiang, China.
- School of Medicine, Ningbo University, Ningbo, Zhejiang, China.
ORCID-Profile: Longfu Jiang, Shanshan Zhuo, Lu Zhang
Förderung
- This work was supported by the Ningbo Major Research and Development Plan Project [Grant Number 2024Z235], Medical Scientific Research Foundation of Zhejiang P…
Zitieren
APA
Wu, H., Jiang, L., Chen, W., Zhuo, S., Shen, J., Zhang, L., Zhang, Y., & Peng, X. (2025). Short‐ to Mid‐Term Efficacy and Safety of Left Bundle Branch Pacing Guided by Continuous Uninterrupted Paced Intracardiac Electrogram Monitoring Targeting Transition to Selective Left Bundle Branch Capture. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70054
Vancouver
Wu H, Jiang L, Chen W, Zhuo S, Shen J, Zhang L, et al. Short‐ to Mid‐Term Efficacy and Safety of Left Bundle Branch Pacing Guided by Continuous Uninterrupted Paced Intracardiac Electrogram Monitoring Targeting Transition to Selective Left Bundle Branch Capture. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.70054
BibTeX
@article{Wu2025,
author = {Wu, Hao and Jiang, Longfu and Chen, Weilin and Zhuo, Shanshan and Shen, Jiabo and Zhang, Lu and Zhang, Yuelin and Peng, Xinhui},
title = {Short‐ to Mid‐Term Efficacy and Safety of Left Bundle Branch Pacing Guided by Continuous Uninterrupted Paced Intracardiac Electrogram Monitoring Targeting Transition to Selective Left Bundle Branch Capture},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.70054}
}
EUVIMED