Evaluation of Dosimetric Effect and Treatment Time by Plan Parameters for Endobronchial Brachytherapy
Progress in Medical Physics · 2017
DOI: 10.14316/pmp.2017.28.2.39 ↗Kurz gefasst
Fachartikel in der Zeitschrift Progress in Medical Physics, 2017. Verfasst von Chang Heon Choi und 5 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Ministry of Health and Welfare, National Research Foundation of Korea.
Abstract (Originalsprache)
using flexible fiber-optic bronchoscopy and high-dose-rate (HDR) afterloading brachytherapy. 4,11) The advantage of brachytherapy is that it allows safe delivery of a tumoricidal This study aims to analyze dose distribution and treatment time of endobronchial brachytherapy (EBBT) by changing the position step size of the dwell position. A solid water phantom and an intraluminal catheter were used in the treatment plan. The treatment plans were generated for 3, 5, 7, and 10 cm treatment lengths, respectively. For each treatment length, the source position step sizes were set as 2.5, 5, and 10 mm. Three reference points were set 1 cm away from the central axis of the catheter, along the axis, for uniform dose distribution. Volumetric dose distribution was calculated to evaluate the dosimetric effect. The total radiation delivery time and total dwell time were estimated for treatment efficiency, which were increased with position step sizes. At half-life time, the differences between the position step sizes in the total radiation delivery time were 18.1, 15.4, 18.0, and 24.0 s for 3, 5, 7, and 10 cm treatment lengths, respectively. The dose distributions were more homogenous by increasing the position step sizes. The dose difference of the reference point was less than 10%. In brachytherapy, this difference can be negligible. For EBBT, the treatment time is the key factor while considering the patient status. To reduce the total treatment time, EBBT can be performed with 2.5 mm position step size.
Förderung
- Ministry of Health and Welfare
- National Research Foundation of Korea
Zitieren
APA
Choi, C. H., Park, J. M., Park, S., Kang, S., Cho, J. D., & Kim, J. (2017). Evaluation of Dosimetric Effect and Treatment Time by Plan Parameters for Endobronchial Brachytherapy. Progress in Medical Physics. https://doi.org/10.14316/pmp.2017.28.2.39
Vancouver
Choi CH, Park JM, Park S, Kang S, Cho JD, Kim J. Evaluation of Dosimetric Effect and Treatment Time by Plan Parameters for Endobronchial Brachytherapy. Progress in Medical Physics. 2017. doi:10.14316/pmp.2017.28.2.39
BibTeX
@article{Choi2017,
author = {Choi, Chang Heon and Park, Jong Min and Park, So-Yeon and Kang, SungHee and Cho, Jin Dong and Kim, Jung-in},
title = {Evaluation of Dosimetric Effect and Treatment Time by Plan Parameters for Endobronchial Brachytherapy},
journal = {Progress in Medical Physics},
year = {2017},
doi = {10.14316/pmp.2017.28.2.39}
}
EUVIMED