A dosimetric evaluation of ovoid and vaginal cylinder applicators in postoperative vaginal brachytherapy for endometrial cancer
Radiation Sciences in Oncology · 27.04.2026 · 1 (1) · 9-16
DOI: 10.33066/rso.2026.6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Sciences in Oncology, online erschienen am 27.04.2026. Verfasst von Hatice Gültekin Büyükbaş und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To compare the dosimetric performance of ovoid and vaginal cylinder applicators for target volume coverage and organs-at-risk (OAR) doses in postoperative vaginal brachytherapy (VBT) for endometrial cancer. Materials and Methods: This retrospective observational study included 32 patients with endometrial cancer treated exclusively with adjuvant vaginal brachytherapy from January 2015 to December 2025. Sixteen patients were treated with a vaginal cylinder and 16 with ovoid applicators. All patients received high-dose-rate brachytherapy delivering a total dose of 21 Gy in 3 fractions, administered three times per week, prescribed to a depth of 5 mm from the applicator surface. CT-based planning was performed, with the high-risk clinical target volume (CTV-High) defined as the upper 3 cm of the vaginal cuff. The bladder and rectum were contoured according to GEC-ESTRO guidelines. Dosimetric evaluation included CTV D90 and CTV V100, as well as OAR dose parameters (D0.1cc, D1cc, D2cc, and D5cc).
Results
No significant differences were observed among applicator types in target volume coverage. Median CTV D90 values were 27.92 Gy and 28.60 Gy in the ovoid and cylinder groups, respectively (p=0.73), while CTV V100 values were 87.40% and 88.51% (p=0.65). Bladder dose parameters were consistently higher in the cylinder group; however, differences in D1cc and D2cc were not statistically significant. In contrast, bladder D0.1cc and D5cc were significantly higher in the cylinder group (p
Zitieren
APA
Büyükbaş, H. G., & Sunğur, E. (2026). A dosimetric evaluation of ovoid and vaginal cylinder applicators in postoperative vaginal brachytherapy for endometrial cancer. Radiation Sciences in Oncology, 1(1), 9-16. https://doi.org/10.33066/rso.2026.6
Vancouver
Büyükbaş HG, Sunğur E. A dosimetric evaluation of ovoid and vaginal cylinder applicators in postoperative vaginal brachytherapy for endometrial cancer. Radiation Sciences in Oncology. 2026;1(1):9-16. doi:10.33066/rso.2026.6
BibTeX
@article{Bykba2026,
author = {Büyükbaş, Hatice Gültekin and Sunğur, Eren},
title = {A dosimetric evaluation of ovoid and vaginal cylinder applicators in postoperative vaginal brachytherapy for endometrial cancer},
journal = {Radiation Sciences in Oncology},
year = {2026},
volume = {1},
number = {1},
pages = {9--16},
doi = {10.33066/rso.2026.6}
}