A fast dosimetric optimization method of intensity modulated brachytherapy (IMBT) treatment plans for cervical cancer
Physics in Medicine & Biology · 14.05.2026 · 71 (9) · 09NT01
DOI: 10.1088/1361-6560/ae63a2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 07.05.2026. Verfasst von Miao Qi und 10 weiteren Autor:innen. Beteiligte Einrichtung: University of Science and Technology of China, School of Nuclear Science and Technology, Hefei 230026, Anhui, People's Republic of China. Hauptthemen laut MEDLINE: Brachytherapy, Uterine Cervical Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, State Administration of Science, Technology and industry for National Defense, Anhui Province Key Research and Development Plan.
Abstract (Originalsprache)
Objective. Intensity-modulated brachytherapy (IMBT) is an innovative technique aimed at achieving anisotropic dose distributions in brachytherapy. This study develops a fast dosimetric optimization method specifically for IMBT plans in cervical cancer. Approach. ARCHER-IMBT was validated against TOPAS in both water phantoms and clinical geometries. Optimization was performed for six intracavitary (IC-BT) cases and one intracavitary/interstitial (IC/IS-BT) case, comparing 50 kVp x-ray and Ir-192 sources. The study also explored the potential of IMBT to achieve comparable dosimetry to IC/IS-BT using only intracavitary applicators. Furthermore, a stochastic uncertainty analysis (200 Monte Carlo scenarios) was conducted to evaluate plan robustness against positional (0.3 mm) and angular (0.2°) perturbations. Main results. ARCHER-IMBT achieved speedup factors exceeding 50× for water phantoms and 350× for clinical cases, with gamma passing rates >98%. The entire optimization process was completed within one minute. Compared to IC-BT, IMBT plans reduced bladder and rectum D 2cc by 3.1% and 15.1% for Ir-192, and by 23.4% and 22.8% for 50 kVp x-rays, respectively. In the IC/IS-BT case, IMBT plans achieved comparable target coverage while potentially eliminating the need for invasive needles. However, uncertainty analysis revealed that the 50 kVp source is highly sensitive to sub-millimeter translational errors (0.3 mm) due to its steep dose gradients, whereas Ir-192 exhibited greater robustness. Significance. This study demonstrates a computationally efficient IMBT optimization platform. The findings highlight the dosimetric benefits of IMBT and its potential to simplify complex IC/IS-BT procedures, while underscoring the stringent mechanical precision required for clinical implementation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Science and Technology of China, School of Nuclear Science and Technology, Hefei 230026, Anhui, People's Republic of China.
- Department of Radiation Oncology, The First Affiliated Hospital of University of Science and Technology of China, Hefei 230026, Anhui, People's Republic of China.
- Anhui Wisdom Technology Co., Ltd, Hefei 230026, Anhui, People's Republic of China.
ORCID-Profile: Miao Qi, Junyi Liu, Yankui Chang, X George Xu
Förderung
- National Natural Science Foundation of China
- State Administration of Science, Technology and industry for National Defense
- Anhui Province Key Research and Development Plan
- Research Funds of the Joint Research Center for Regional Diseases of IHM
Zitieren
APA
Qi, M., Liu, J., Li, S., Chang, Y., Zhou, J., Cheng, Y., Yan, B., Liu, Y., Wu, A., Xi, P., & Xu, X. G. (2026). A fast dosimetric optimization method of intensity modulated brachytherapy (IMBT) treatment plans for cervical cancer. Physics in Medicine & Biology, 71(9), 09NT01. https://doi.org/10.1088/1361-6560/ae63a2
Vancouver
Qi M, Liu J, Li S, Chang Y, Zhou J, Cheng Y, et al. A fast dosimetric optimization method of intensity modulated brachytherapy (IMBT) treatment plans for cervical cancer. Physics in Medicine & Biology. 2026;71(9):09NT01. doi:10.1088/1361-6560/ae63a2
BibTeX
@article{Qi2026,
author = {Qi, Miao and Liu, Junyi and Li, Shijun and Chang, Yankui and Zhou, Jieping and Cheng, Yong and Yan, Bing and Liu, Yunqin and Wu, Aidong and Xi, Pei and Xu, X George},
title = {A fast dosimetric optimization method of intensity modulated brachytherapy (IMBT) treatment plans for cervical cancer},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {9},
pages = {09NT01},
doi = {10.1088/1361-6560/ae63a2}
}