An improved Scale-Invariant Feature Transform-based method for detecting tumor tissue motion induced by respiration

Qingya Pan, Shengjie Luan iD, Fuke Zhang, Linzhao Tian, Guishu Wu, Yizhong Fan

PLOS One · 24.06.2026 · 21 (6) · e0330578

DOI: 10.1371/journal.pone.0330578 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 24.06.2026. Verfasst von Qingya Pan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of ChemoRadiotherapy Oncology, The Center Hospital of QingHe, HeBei, China. Hauptthemen laut MEDLINE: Respiration. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Plan Projects of Tibet Autonomous Region.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Scale-Invariant Feature Transform (SIFT) features are widely used in target recognition and tracking. This study aimed to exploit the robust performance of the SIFT algorithm to accurately calculate tumor tissue displacement during respiratory motion. Materials and methods A thoracic phantom was employed in this study. Eight synthetic nodules with different shapes and gray values were inserted into the phantom. First, the nodules were displaced upward, downward, leftward, and rightward by 10 pixels to simulate motion in different directions during respiration. The nodules were then rotated clockwise and counterclockwise by 5°, 10°, 30°, and 45°. Subsequently, the SIFT and cross-correlation algorithms were applied to analyze the phantoms. Finally, a t-test was used to assess differences among motion directions.

Results

The t-test result indicated no significant difference in the detection of moving phantom across all motion directions (p > 0.05). No statistically significant difference was observed between SIFT and cross-correlation in detecting translational motion. In contrast, the results obtained from rotating phantoms demonstrated that SIFT could effectively detect rotational distortion.

Conclusion

The SIFT algorithm can be used to calculate tissue distortion caused by thoracic motion during respiration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RespirationAlgorithmsPhantoms, ImagingHumansMovementTomography, X-Ray ComputedMotion

Autor:innen und Institutionen

  • Department of ChemoRadiotherapy Oncology, The Center Hospital of QingHe, HeBei, China.

ORCID-Profile: Shengjie Luan

Förderung

  • Science and Technology Plan Projects of Tibet Autonomous Region

Zitieren

APA

Pan, Q., Luan, S., Zhang, F., Tian, L., Wu, G., & Fan, Y. (2026). An improved Scale-Invariant Feature Transform-based method for detecting tumor tissue motion induced by respiration. PLOS One, 21(6), e0330578. https://doi.org/10.1371/journal.pone.0330578

Vancouver

Pan Q, Luan S, Zhang F, Tian L, Wu G, Fan Y. An improved Scale-Invariant Feature Transform-based method for detecting tumor tissue motion induced by respiration. PLOS One. 2026;21(6):e0330578. doi:10.1371/journal.pone.0330578

BibTeX
@article{Pan2026,
  author = {Pan, Qingya and Luan, Shengjie and Zhang, Fuke and Tian, Linzhao and Wu, Guishu and Fan, Yizhong},
  title = {An improved Scale-Invariant Feature Transform-based method for detecting tumor tissue motion induced by respiration},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {6},
  pages = {e0330578},
  doi = {10.1371/journal.pone.0330578}
}
Kostenlos starten →