EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A non-enzymatic doxycycline absorbance sensor based on manganese-doped zinc sulfide nanoparticles coated with chitosan

Son Hai Nguyen iD, Mai Thi Tran iD

PLOS One · 14.07.2025 · 20 (7) · e0328304

DOI: 10.1371/journal.pone.0328304 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 14.07.2025. Verfasst von Son Hai Nguyen und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam. Hauptthemen laut MEDLINE: Chitosan, Sulfides, Manganese, Doxycycline. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The need for doxycycline detection is urgent because it is a vital antibiotic extensively utilized to combat bacterial diseases in humans and animals, and it is now at the forefront of the global battle against antibiotic resistance. Our research introduces an absorbance biosensor that employs chitosan-capped ZnS nanoparticles doped with manganese without an enzyme to address this critical need. Our study highlights the sensor’s robust performance with nearly 100% recovery and stability over time to detect doxycycline from 0 to 72.2 pM. Limits of detection and quantification were achieved at 4.5 pM and 15 pM, respectively, using simple absorbance measurements, with effective operation demonstrated across various media. The sensor also obtains excellent selectivity when testing with other analytes, including glucose, amoxicillin, tetracycline, penicillin, ampicillin, and cephalexin. The capabilities of these ZnS: Mn/Chitosan-based sensors mark a significant advancement in antibiotic monitoring, offering promising applications in clinical settings for patient care and environmental surveillance, thereby playing a critical role in curbing the spread of antibiotic resistance globally.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChitosanSulfidesManganeseDoxycyclineBiosensing TechniquesAnti-Bacterial AgentsZinc CompoundsNanoparticlesHumansLimit of Detection

Substanzen

ChitosanSulfidesManganeseDoxycyclinezinc sulfideAnti-Bacterial AgentsZinc Compounds

Autor:innen und Institutionen

  • School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam.
  • College of Engineering and Computer Science, VinUniversity, Hanoi, Vietnam.
  • VinUni-Illinois Smart Health Center, VinUniversity, Hanoi, Vietnam.

ORCID-Profile: Son Hai Nguyen, Mai Thi Tran

Zitieren

APA

Nguyen, S. H., & Tran, M. T. (2025). A non-enzymatic doxycycline absorbance sensor based on manganese-doped zinc sulfide nanoparticles coated with chitosan. PLOS One, 20(7), e0328304. https://doi.org/10.1371/journal.pone.0328304

Vancouver

Nguyen SH, Tran MT. A non-enzymatic doxycycline absorbance sensor based on manganese-doped zinc sulfide nanoparticles coated with chitosan. PLOS One. 2025;20(7):e0328304. doi:10.1371/journal.pone.0328304

BibTeX
@article{Nguyen2025,
  author = {Nguyen, Son Hai and Tran, Mai Thi},
  title = {A non-enzymatic doxycycline absorbance sensor based on manganese-doped zinc sulfide nanoparticles coated with chitosan},
  journal = {PLOS One},
  year = {2025},
  volume = {20},
  number = {7},
  pages = {e0328304},
  doi = {10.1371/journal.pone.0328304}
}
Kostenlos starten →