Selective ratiometric fluorescent detection of chlortetracycline in environmental water based on hydrolysis-induced emission
Microchimica Acta · 2025-08 · 192 (8)
DOI: 10.1007/s00604-025-07394-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 23.07.2025. Verfasst von Shiyu Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Advanced Materials of Tropical Island Resources of Ministry of Education, School of Chemistry and Chemical Engineering, Hainan Univ…. Hauptthemen laut MEDLINE: Chlortetracycline, Water Pollutants, Chemical, Fluorescent Dyes, Anti-Bacterial Agents. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China, the Specific Research Fund of the Innovation Platform for Academicians of Hainan Province, China, the Innovation Platform for Academicians of Hainan Province, China.
Abstract (Originalsprache)
For specific determination of chlortetracycline (CTC) among tetracycline antibiotics (TCs), the current study focused on the hydrolysis effect of TCs. In water, CTC was hydrolyzed into isochlortetracycline (iso-CTC) along with blue fluorescence, but other TCs remained stable without blue fluorescence. CTC was thus identified within TCs based on hydrolysis-induced emission. To improve signal stability, Mn-doped ZnS (Mn:ZnS) quantum dots (QDs) that exhibited red luminescence were introduced to achieve ratiometric sensing. After adding CTC to Mn:ZnS QDs, the red emission of Mn:ZnS QDs was decreased owing to inner filter effect and dynamic quenching effect, whereas blue emission was observed due to the hydrolysis of CTC. This ratiometric method quantified CTC in the concentration range 0.3-50 μM with a response time of 60 min and a detection limit of 94 nM. This ratiometric method was employed to detect CTC in environmental water. A sensing platform that combined test strips and a smartphone was constructed to visualize the determination of CTC. This work proposes a hydrolysis-based mechanism for selective recognition of CTC among TCs, which facilitates to assess the hazard rating of the environmental water polluted by TCs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Advanced Materials of Tropical Island Resources of Ministry of Education, School of Chemistry and Chemical Engineering, Hainan University, Haikou, 570228, China.
- Key Laboratory of Advanced Materials of Tropical Island Resources of Ministry of Education, School of Chemistry and Chemical Engineering, Hainan University, Haikou, 570228, China. lihuihui@hainanu.edu.cn.
- Department of Clinical Laboratory, Xiamen Huli Guoyu Clinic, Co., Ltd., Xiamen, 361000, China. xiamenhaijin@163.com.
- Key Laboratory of Advanced Materials of Tropical Island Resources of Ministry of Education, School of Chemistry and Chemical Engineering, Hainan University, Haikou, 570228, China. panqinhe@163.com.
Förderung
- National Natural Science Foundation of China
- the Specific Research Fund of the Innovation Platform for Academicians of Hainan Province, China
- the Innovation Platform for Academicians of Hainan Province, China
Zitieren
APA
Li, S., Li, H., Li, Y., Guo, D. Y., Han, J., Zhang, Y., & Pan, Q. (2025). Selective ratiometric fluorescent detection of chlortetracycline in environmental water based on hydrolysis-induced emission. Microchimica Acta, 192(8). https://doi.org/10.1007/s00604-025-07394-5
Vancouver
Li S, Li H, Li Y, Guo DY, Han J, Zhang Y, et al. Selective ratiometric fluorescent detection of chlortetracycline in environmental water based on hydrolysis-induced emission. Microchimica Acta. 2025;192(8). doi:10.1007/s00604-025-07394-5
BibTeX
@article{Li2025,
author = {Li, Shiyu and Li, Huihui and Li, Yu and Guo, Dong-Yu and Han, Jingxuan and Zhang, Yiyuan and Pan, Qinhe},
title = {Selective ratiometric fluorescent detection of chlortetracycline in environmental water based on hydrolysis-induced emission},
journal = {Microchimica Acta},
year = {2025},
volume = {192},
number = {8},
doi = {10.1007/s00604-025-07394-5}
}
EUVIMED