EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Disposable non-enzymatic impedimetric biosensor using Mn-doped ZnS-chitosan nanocomposite for tetracycline detection

Trong-Du Nguyen, Huy Quang Nguyen iD, Mai Thi Tran iD, Son Hai Nguyen iD, Cuong Danh Do iD

PLOS One · 27.02.2026 · 21 (2) · e0344103

DOI: 10.1371/journal.pone.0344103 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 27.02.2026. Verfasst von Trong-Du Nguyen und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam. Hauptthemen laut MEDLINE: Biosensing Techniques, Chitosan, Nanocomposites, Manganese. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Smart Green Transformation Center (Green-X), VinUniversity.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring antibiotic residues in aquaculture water is critical for food safety, environmental protection, and antimicrobial stewardship. Here, we present a proof-of-concept disposable, non-enzymatic impedimetric biosensor for the rapid and selective detection of tetracycline. The sensor employs interdigitated electrodes functionalized with a manganese-doped zinc sulfide-chitosan nanocomposite, providing a stable, conductive, and environmentally friendly sensing interface. The successful synthesis of the nanocomposite was confirmed using scanning electron microscopy, high-resolution transmission electron microscopy, X-ray diffraction, energy-dispersive X-ray spectroscopy, and Fourier transform infrared spectroscopy. Using electrochemical impedance spectroscopy, the device exhibits a linear response over the range of 62.5–1000 nM tetracycline, with a limit of detection of 42 nM and a limit of quantification of 138 nM. It also displays strong selectivity over other common antibiotics, including ampicillin, amoxicillin, cephalexin, doxycycline, penicillin, and non-antibiotic interferent, glucose, as well as excellent reproducibility and operational stability under repeated measurements. The sensor can detect tetracycline in lake, tap, and bottled water with linear responses across the same concentration range. The combination of biocompatible, low-cost materials and simple fabrication supports single-use deployment and scalability. These results demonstrate the potential of manganese-doped zinc sulfide-chitosan nanocomposite-based impedimetric biosensors as practical platforms for on-site monitoring of antibiotic residues in aquaculture water.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesChitosanNanocompositesManganeseSulfidesZinc CompoundsTetracyclineAnti-Bacterial AgentsDielectric SpectroscopyLimit of DetectionReproducibility of ResultsElectrodes

Substanzen

ChitosanManganeseSulfidesZinc CompoundsTetracyclinezinc sulfideAnti-Bacterial Agents

Autor:innen und Institutionen

  • School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi, Vietnam.
  • College of Engineering and Computer Science, VinUniversity, Hanoi, Vietnam.
  • Smart Green Transformation Center (Green-X), VinUniversity, Hanoi, Vietnam.

ORCID-Profile: Huy Quang Nguyen, Mai Thi Tran, Son Hai Nguyen, Cuong Danh Do

Förderung

  • Smart Green Transformation Center (Green-X), VinUniversity

Zitieren

APA

Nguyen, T. D., Nguyen, H. Q., Tran, M. T., Nguyen, S. H., & Do, C. D. (2026). Disposable non-enzymatic impedimetric biosensor using Mn-doped ZnS-chitosan nanocomposite for tetracycline detection. PLOS One, 21(2), e0344103. https://doi.org/10.1371/journal.pone.0344103

Vancouver

Nguyen TD, Nguyen HQ, Tran MT, Nguyen SH, Do CD. Disposable non-enzymatic impedimetric biosensor using Mn-doped ZnS-chitosan nanocomposite for tetracycline detection. PLOS One. 2026;21(2):e0344103. doi:10.1371/journal.pone.0344103

BibTeX
@article{Nguyen2026,
  author = {Nguyen, Trong-Du and Nguyen, Huy Quang and Tran, Mai Thi and Nguyen, Son Hai and Do, Cuong Danh},
  title = {Disposable non-enzymatic impedimetric biosensor using Mn-doped ZnS-chitosan nanocomposite for tetracycline detection},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {2},
  pages = {e0344103},
  doi = {10.1371/journal.pone.0344103}
}
Kostenlos starten →