EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination

Hikari Tsukamoto iD, Hiroshi Muraishi, Ryoji Enomoto, Hideaki Katagiri iD, Mika Kagaya, Takara Watanabe iD, Takahiro Mizoguchi, Masaya Fukumoto, Daisuke Kano, Yusuke Watanabe, Kazuya Sakaguchi iD, Hiromichi Ishiyama

PLOS One · 2025

DOI: 10.1371/journal.pone.0325586 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Hikari Tsukamoto und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan. Hauptthemen laut MEDLINE: Lutetium, Radioisotopes, Gamma Cameras. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Special Research Grants of the School of Allied Health Sciences, Kitasato University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we developed an omnidirectional rotating Compton camera that was capable of imaging low-level radioactive contamination caused by 177 Lu-oxodotreotide, a novel radiopharmaceutical that has recently been attracting attention in nuclear medicine. The detector employs a compact design that comprises only six scintillator crystals mounted on a motorized rotating stage. By optimizing the crystal type and size, and optimizing the interval between crystals, the detector is able to adapt to a wide range of environmental conditions, including observable gamma-ray energies, dose rates, and angular resolution. Monte Carlo simulations using Geant4 were conducted to optimize the configuration of the detector. Based on the results of the simulation, a prototype detector using six 3.5 cm cubic CaF 2 ( Eu ) crystals was developed for visualizing 177 Lu-contaminated sites. The experimental results demonstrated that the detector could successfully visualize an unsealed 177 Lu -oxodotreotide source with high sensitivity without being affected by gamma rays from 99 TC, which is also present in nuclear medicine facilities. The developed rotating Compton camera technology is anticipated to serve as a reliable environmental monitoring tool in nuclear medicine facilities. Through its ability to rapidly detect radioactive contamination, this detector has the potential to reduce the radiation exposure risks for both medical professionals and the general public.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LutetiumRadioisotopesGamma CamerasMonte Carlo MethodGamma RaysHumansSomatostatinRadiopharmaceuticals

Substanzen

LutetiumRadioisotopesLutetium-177SomatostatinRadiopharmaceuticals

Autor:innen und Institutionen

  • School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan.
  • Department of Radiological Technology, Tokai University Hospital, Isehara, Kanagawa, Japan.
  • College of Science, Ibaraki University, Mito, Ibaraki, Japan.
  • National Institute of Technology, Sendai College, Sendai, Miyagi, Japan.
  • Department of Pharmacy, National Cancer Center Hospital East, Kashiwa, Chiba, Japan.
  • Department of Radiology and Radiation Oncology, Kitasato University, Sagamihara, Kanagawa, Japan.

ORCID-Profile: Hikari Tsukamoto, Hideaki Katagiri, Takara Watanabe, Kazuya Sakaguchi

Förderung

  • Japan Society for the Promotion of Science
  • Special Research Grants of the School of Allied Health Sciences, Kitasato University

Zitieren

APA

Tsukamoto, H., Muraishi, H., Enomoto, R., Katagiri, H., Kagaya, M., Watanabe, T., Mizoguchi, T., Fukumoto, M., Kano, D., Watanabe, Y., Sakaguchi, K., & Ishiyama, H. (2025). Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination. PLOS One. https://doi.org/10.1371/journal.pone.0325586

Vancouver

Tsukamoto H, Muraishi H, Enomoto R, Katagiri H, Kagaya M, Watanabe T, et al. Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination. PLOS One. 2025. doi:10.1371/journal.pone.0325586

BibTeX
@article{Tsukamoto2025,
  author = {Tsukamoto, Hikari and Muraishi, Hiroshi and Enomoto, Ryoji and Katagiri, Hideaki and Kagaya, Mika and Watanabe, Takara and Mizoguchi, Takahiro and Fukumoto, Masaya and Kano, Daisuke and Watanabe, Yusuke and Sakaguchi, Kazuya and Ishiyama, Hiromichi},
  title = {Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0325586}
}
Kostenlos starten →