Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination
PLOS One · 2025
DOI: 10.1371/journal.pone.0325586 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Hikari Tsukamoto und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan. Hauptthemen laut MEDLINE: Lutetium, Radioisotopes, Gamma Cameras. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Special Research Grants of the School of Allied Health Sciences, Kitasato University.
Abstract (Originalsprache)
In this study, we developed an omnidirectional rotating Compton camera that was capable of imaging low-level radioactive contamination caused by 177 Lu-oxodotreotide, a novel radiopharmaceutical that has recently been attracting attention in nuclear medicine. The detector employs a compact design that comprises only six scintillator crystals mounted on a motorized rotating stage. By optimizing the crystal type and size, and optimizing the interval between crystals, the detector is able to adapt to a wide range of environmental conditions, including observable gamma-ray energies, dose rates, and angular resolution. Monte Carlo simulations using Geant4 were conducted to optimize the configuration of the detector. Based on the results of the simulation, a prototype detector using six 3.5 cm cubic CaF 2 ( Eu ) crystals was developed for visualizing 177 Lu-contaminated sites. The experimental results demonstrated that the detector could successfully visualize an unsealed 177 Lu -oxodotreotide source with high sensitivity without being affected by gamma rays from 99 TC, which is also present in nuclear medicine facilities. The developed rotating Compton camera technology is anticipated to serve as a reliable environmental monitoring tool in nuclear medicine facilities. Through its ability to rapidly detect radioactive contamination, this detector has the potential to reduce the radiation exposure risks for both medical professionals and the general public.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan.
- Department of Radiological Technology, Tokai University Hospital, Isehara, Kanagawa, Japan.
- College of Science, Ibaraki University, Mito, Ibaraki, Japan.
- National Institute of Technology, Sendai College, Sendai, Miyagi, Japan.
- Department of Pharmacy, National Cancer Center Hospital East, Kashiwa, Chiba, Japan.
- Department of Radiology and Radiation Oncology, Kitasato University, Sagamihara, Kanagawa, Japan.
ORCID-Profile: Hikari Tsukamoto, Hideaki Katagiri, Takara Watanabe, Kazuya Sakaguchi
Förderung
- Japan Society for the Promotion of Science
- Special Research Grants of the School of Allied Health Sciences, Kitasato University
Zitieren
APA
Tsukamoto, H., Muraishi, H., Enomoto, R., Katagiri, H., Kagaya, M., Watanabe, T., Mizoguchi, T., Fukumoto, M., Kano, D., Watanabe, Y., Sakaguchi, K., & Ishiyama, H. (2025). Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination. PLOS One. https://doi.org/10.1371/journal.pone.0325586
Vancouver
Tsukamoto H, Muraishi H, Enomoto R, Katagiri H, Kagaya M, Watanabe T, et al. Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination. PLOS One. 2025. doi:10.1371/journal.pone.0325586
BibTeX
@article{Tsukamoto2025,
author = {Tsukamoto, Hikari and Muraishi, Hiroshi and Enomoto, Ryoji and Katagiri, Hideaki and Kagaya, Mika and Watanabe, Takara and Mizoguchi, Takahiro and Fukumoto, Masaya and Kano, Daisuke and Watanabe, Yusuke and Sakaguchi, Kazuya and Ishiyama, Hiromichi},
title = {Development of an omnidirectional rotating Compton camera for imaging 177Lu radioactive contamination},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0325586}
}
EUVIMED