A Monte Carlo study comparing dead-time losses of a gamma camera between tungsten functional paper and lead sheet for dosimetry in targeted radionuclide therapy with Lu-177

Kohei Nakanishi, Naotoshi Fujita, Haruna Iwanaga, Yuki Asano, Shinji Abe, Ryuichi Nishii, Katsuhiko Kato

Annals of Nuclear Medicine · 2025

DOI: 10.1007/s12149-024-01987-5 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Annals of Nuclear Medicine, 2025. Verfasst von Kohei Nakanishi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Functional Medical Imaging, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, …. Hauptthemen laut MEDLINE: Monte Carlo Method, Gamma Cameras, Lead, Lutetium. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS Grant-in-Aid for Young Scientists, Nagoya University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Dead-time loss is reported to be non-negligible for some patients with a high tumor burden in Lu-177 radionuclide therapy, even if the administered activity is 7.4 GBq. Hence, we proposed a simple method to shorten the apparent dead time and reduce dead-time loss using a thin lead sheet in previous work. The collimator surface of the gamma camera was covered with a lead sheet in our proposed method. While allowing the detection of 208-keV gamma photons of Lu-177 that penetrate the sheet, photons with energies lower than 208 keV, which cause dead-time loss, were shielded. In this study, we evaluated the usefulness of tungsten functional paper (TFP) for the proposed method using Monte Carlo simulation.

Methods

The count rates in imaging of Lu-177 administered to patients were simulated with the International Commission on Radiological Protection (ICRP) 110 phantom using the GATE Monte Carlo simulation toolkit. The simulated gamma cameras with a 0.5-mm lead sheet, 1.2-mm TFP, or no filter were positioned closely on the anterior and posterior sides of the phantom. The apparent dead times and dead-time losses at 24 h after administration were calculated for an energy window of 208 keV ± 10%. Moreover, the dead-time losses at 24–120 h were analytically assessed using activity excretion data of Lu-177-DOTATATE.

Results

The dead-time loss without a filter was 5% even 120 h after administration in patients with a high tumor burden and slow excretion, while those with a lead sheet and TFP were 0.22 and 0.58 times less than those with no filter, respectively. The count rates with the TFP were 1.3 times higher than those with the lead sheet, and the TFP could maintain primary count rates at 91–94% of those without a filter.

Conclusions

Although the apparent dead time and dead-time loss with the lead sheet were shorter and less than those with TFP, those with TFP were superior to those without a filter. The advantage of TFP over the lead sheet is that the decrease in primary count rates was less.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monte Carlo MethodGamma CamerasLeadLutetiumRadiometryRadioisotopesTungstenHumansPhantoms, ImagingTime Factors

Stichwörter der Autor:innen

Dead timeGamma cameraLu-177Monte Carlo simulationQuantification

Substanzen

LeadLutetiumRadioisotopesLutetium-177Tungsten

Autor:innen und Institutionen

  • Functional Medical Imaging, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Hi…
  • Department of Radiological Technology, Nagoya University Hospital, 65 Tsurumai-Cho, Showa-Ku, Nagoya, Aichi, Japan.
  • Department of Radiological and Medical Laboratory Sciences, Department of Integrated Health Science, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Higashi-Ku, Nagoya, Aichi, Japan.
  • Medical Imaging Engineering, Division of AdvancedInformation Health Sciences, Department of Integrated Health Sciences, Biomedical Imaging Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Hi…

Förderung

  • JSPS Grant-in-Aid for Young Scientists
  • Nagoya University

Zitieren

APA

Nakanishi, K., Fujita, N., Iwanaga, H., Asano, Y., Abe, S., Nishii, R., & Kato, K. (2025). A Monte Carlo study comparing dead-time losses of a gamma camera between tungsten functional paper and lead sheet for dosimetry in targeted radionuclide therapy with Lu-177. Annals of Nuclear Medicine. https://doi.org/10.1007/s12149-024-01987-5

Vancouver

Nakanishi K, Fujita N, Iwanaga H, Asano Y, Abe S, Nishii R, et al. A Monte Carlo study comparing dead-time losses of a gamma camera between tungsten functional paper and lead sheet for dosimetry in targeted radionuclide therapy with Lu-177. Annals of Nuclear Medicine. 2025. doi:10.1007/s12149-024-01987-5

BibTeX
@article{Nakanishi2025,
  author = {Nakanishi, Kohei and Fujita, Naotoshi and Iwanaga, Haruna and Asano, Yuki and Abe, Shinji and Nishii, Ryuichi and Kato, Katsuhiko},
  title = {A Monte Carlo study comparing dead-time losses of a gamma camera between tungsten functional paper and lead sheet for dosimetry in targeted radionuclide therapy with Lu-177},
  journal = {Annals of Nuclear Medicine},
  year = {2025},
  doi = {10.1007/s12149-024-01987-5}
}
Kostenlos starten →