EUVIMEDEUVIMED entdecken
Crossref

Influence of radionuclide cascade decay characteristics on non-collinear coincidence imaging performance: a GATE-based Monte Carlo simulation study

Leonid L Nkuba iD, Enock M Mwita iD, Innocent J Junior, Elisha D Edmund, Innocent J Lugendo iD

Biomedical Physics & Engineering Express · 2026

DOI: 10.1088/2057-1976/aeaeee ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, 2026. Verfasst von Leonid L Nkuba und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear Technology Directorate, Tanzania Atomic Energy Commission, PO Box 1585 Dodoma, Tanzania. Hauptthemen laut MEDLINE: Monte Carlo Method, Radioisotopes, Positron-Emission Tomography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Tanzania Atomic Energy Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated the influence of radionuclide cascade decay characteristics on the performance of a non-collinear cascade coincidence imaging modality using Monte Carlo simulations implemented in the GATE platform. To evaluate their imaging performance, four cascade gamma-emitting radionuclides, namely 43 K, 73 Se, 111 In and 177 Lu were simulated at the center of the field of view of a small-animal positron emission tomography scanner. The scanner is equipped with dual-layer Cerium-doped Gadolinium Oxyorthosilicate (GSO:Ce) detectors. The effects of cascade gamma-ray energies, emission probabilities, and intermediate-state half-lives on cascade coincidence detection efficiency (CCDE), sensitivity, random coincidence contribution, noise performance, scatter fraction (SF) and spatial resolution were evaluated. Simulated intermediate-state half-lives were compared with reference data to validate the simulation framework. The results showed that the simulated intermediate-state half-lives were in good agreement with the reference values, confirming the validity of the simulation model. All radionuclides achieved identical isotropic spatial resolution of approximately 0.477 mm full width at half maximum, indicating that spatial resolution is primarily determined by detector geometry and the reconstruction algorithm rather than radionuclide decay characteristics. In contrast, the remaining imaging performance metrics strongly depended on cascade decay properties and coincidence timing conditions. 111 In exhibited the highest sensitivity (15058.8 cps/MBq) and CCDE, but also produced the highest random-to-true coincidence ratio (24.6%) due to its relatively long intermediate-state half-life and wider coincidence timing window. 73 Se achieved the highest noise-equivalent cascade count rate, while SFs remained negligible for most radionuclides. Therefore, under idealized Monte Carlo simulation conditions, radionuclide cascade decay characteristics, energy window and coincidence timing window optimization play critical roles in determining the performance of non-collinear cascade coincidence imaging systems. The reported performance represents an ideal detector model and should be validated under realistic detector and experimental conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monte Carlo MethodRadioisotopesPositron-Emission TomographyComputer SimulationPhantoms, ImagingHalf-LifeLutetiumAnimalsGamma RaysAlgorithms

Stichwörter der Autor:innen

GATEMonte-Carlo studycascade gamma raysnon-collinear coincidence imagingradionuclide decay characteristics

Substanzen

RadioisotopesLutetium

Autor:innen und Institutionen

  • Nuclear Technology Directorate, Tanzania Atomic Energy Commission, PO Box 1585 Dodoma, Tanzania.
  • Department of Physics, University of Dar es Salaam, PO Box 35063 Dar es Salaam, Tanzania.
  • Dar es Salaam University College of Education, PO Box 2329 Dar es Salaam, Tanzania.

ORCID-Profile: Leonid L Nkuba, Enock M Mwita, Innocent J Lugendo

Förderung

  • Tanzania Atomic Energy Commission

Zitieren

APA

Nkuba, L. L., Mwita, E. M., Junior, I. J., Edmund, E. D., & Lugendo, I. J. (2026). Influence of radionuclide cascade decay characteristics on non-collinear coincidence imaging performance: a GATE-based Monte Carlo simulation study. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/aeaeee

Vancouver

Nkuba LL, Mwita EM, Junior IJ, Edmund ED, Lugendo IJ. Influence of radionuclide cascade decay characteristics on non-collinear coincidence imaging performance: a GATE-based Monte Carlo simulation study. Biomedical Physics & Engineering Express. 2026. doi:10.1088/2057-1976/aeaeee

BibTeX
@article{Nkuba2026,
  author = {Nkuba, Leonid L and Mwita, Enock M and Junior, Innocent J and Edmund, Elisha D and Lugendo, Innocent J},
  title = {Influence of radionuclide cascade decay characteristics on non-collinear coincidence imaging performance: a GATE-based Monte Carlo simulation study},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  doi = {10.1088/2057-1976/aeaeee}
}
Kostenlos starten →