EUVIMEDEUVIMED entdecken
Crossref

Developing a Computer Vision Model to Automate Quantitative Measurement of Hip-Knee-Ankle Angle in Total Hip and Knee Arthroplasty Patients

Irene L Tanner, Ken Ye, Miles S Moore, Albert J Rechenmacher, Michelle M Ramirez, Steven Z George, Michael P Bolognesi, Maggie E Horn

The Journal of Arthroplasty · 2024-09 · 39 (9) · 2225-2233

DOI: 10.1016/j.arth.2024.04.062 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-09. Verfasst von Irene L Tanner und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biostatistics and Bioinformatics, Duke University School of Medicine, Durham, North Carolina. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Arthroplasty, Replacement, Hip. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Increasing deformity of the lower extremities, as measured by the hip-knee-ankle angle (HKAA), is associated with poor patient outcomes after total hip and knee arthroplasty (THA, TKA). Automated calculation of HKAA is imperative to reduce the burden on orthopaedic surgeons. We proposed a detection-based deep learning (DL) model to calculate HKAA in THA and TKA patients and assessed the agreement between DL-derived HKAAs and manual measurement. METHODS: We retrospectively identified 1,379 long-leg radiographs (LLRs) from patients scheduled for THA or TKA within an academic medical center. There were 1,221 LLRs used to develop the model (randomly split into 70% training, 20% validation, and 10% held-out test sets); 158 LLRs were considered "difficult," as the femoral head was difficult to distinguish from surrounding tissue. There were 2 raters who annotated the HKAA of both lower extremities, and inter-rater reliability was calculated to compare the DL-derived HKAAs with manual measurement within the test set. RESULTS: The DL model achieved a mean average precision of 0.985 on the test set. The average HKAA of the operative leg was 173.05 ± 4.54°; the nonoperative leg was 175.55 ± 3.56°. The inter-rater reliability between manual and DL-derived HKAA measurements on the operative leg and nonoperative leg indicated excellent reliability (intraclass correlation (2,k) = 0.987 [0.96, 0.99], intraclass correlation (2, k) = 0.987 [0.98, 0.99, respectively]). The standard error of measurement for the DL-derived HKAA for the operative and nonoperative legs was 0.515° and 0.403°, respectively. CONCLUSIONS: A detection-based DL algorithm can calculate the HKAA in LLRs and is comparable to that calculated by manual measurement. The algorithm can detect the bilateral femoral head, knee, and ankle joints with high precision, even in patients where the femoral head is difficult to visualize.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeArthroplasty, Replacement, HipHumansRetrospective StudiesFemaleMaleAgedMiddle AgedKnee JointHip JointDeep LearningAnkle JointReproducibility of ResultsRadiography

Stichwörter der Autor:innen

computer visiondeep learninghip-knee-ankle anglelower extremity alignmenttotal hip arthroplastytotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Biostatistics and Bioinformatics, Duke University School of Medicine, Durham, North Carolina.
  • Trinity College of Arts & Sciences, Duke University, Durham, North Carolina.
  • Physical Therapy Division, Duke University School of Medicine, Durham, North Carolina.
  • Department of Orthopaedic Surgery, Duke University School of Medicine, Durham, North Carolina.
  • Department of Population Health Sciences, Department of Orthopaedic Surgery, Duke University School of Medicine, Durham, North Carolina.
  • Department of Orthopaedic Surgery, Department of Population Health Sciences, Duke Clinical Research Institute, Duke University, Durham, North Carolina.

Zitieren

APA

Tanner, I. L., Ye, K., Moore, M. S., Rechenmacher, A. J., Ramirez, M. M., George, S. Z., Bolognesi, M. P., & Horn, M. E. (2024). Developing a Computer Vision Model to Automate Quantitative Measurement of Hip-Knee-Ankle Angle in Total Hip and Knee Arthroplasty Patients. The Journal of Arthroplasty, 39(9), 2225-2233. https://doi.org/10.1016/j.arth.2024.04.062

Vancouver

Tanner IL, Ye K, Moore MS, Rechenmacher AJ, Ramirez MM, George SZ, et al. Developing a Computer Vision Model to Automate Quantitative Measurement of Hip-Knee-Ankle Angle in Total Hip and Knee Arthroplasty Patients. The Journal of Arthroplasty. 2024;39(9):2225-2233. doi:10.1016/j.arth.2024.04.062

BibTeX
@article{Tanner2024,
  author = {Tanner, Irene L and Ye, Ken and Moore, Miles S and Rechenmacher, Albert J and Ramirez, Michelle M and George, Steven Z and Bolognesi, Michael P and Horn, Maggie E},
  title = {Developing a Computer Vision Model to Automate Quantitative Measurement of Hip-Knee-Ankle Angle in Total Hip and Knee Arthroplasty Patients},
  journal = {The Journal of Arthroplasty},
  year = {2024},
  volume = {39},
  number = {9},
  pages = {2225--2233},
  doi = {10.1016/j.arth.2024.04.062}
}
Kostenlos starten →