Reliability of Markerless 2D Video Analysis for Calculating Gait Joint Angles in Uncontrolled Environments
Sensors · 2026
DOI: 10.3390/s26196229 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Sagrario Pérez-de la Cruz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nursery, Physiotherapy and Medicine, University of Almería, 04120 Almería, Spain. Hauptthemen laut MEDLINE: Video Recording, Gait, Gait Analysis. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Traditional 3D gait analysis constrains natural movement variability due to artificial laboratory settings; thus, this study evaluated the intra- and inter-rater reliability of a low-cost, 2D markerless smartphone video protocol for assessing lower limb sagittal kinematics in an unconstrained environment.
Methods
Forty-five healthy young adults walked at a self-selected speed in a non-laboratory corridor, where sagittal hip, knee, and ankle angles were recorded at 60 fps and analyzed using Kinovea® software by two independent raters, with one rater repeating measurements seven days later.
Results
Inter-rater reliability ranged from moderate to good across most joint variables (ICC = 0.628–0.789), except for the ankle during loading response, which showed poor consistency (ICC = 0.381). Between-session intra-rater reliability was generally lower, ranging from poor to moderate (ICC = 0.278–0.580), with the lowest values observed at the hip (ICC = 0.278) and ankle (ICC = 0.391) during loading response. Minimal Detectable Change (MDC95) values ranged from 7.07° to 8.95° for inter-rater assessments and from 7.40° to 16.55° for intra-rater assessments, with Bland–Altman analysis displaying wide limits of agreement longitudinally.
Conclusions
In conclusion, while prior observer training standardizes criteria for immediate cross-sectional evaluations, the protocol’s high sensitivity to measurement variability and unconstrained motor execution limits its clinical application for longitudinal tracking across different sessions. Between-session intra-rater variability reflects evaluator subjectivity in manual frame selection and landmark digitization over time when no physical markers are present, rather than biological gait fluctuations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nursery, Physiotherapy and Medicine, University of Almería, 04120 Almería, Spain.
- Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain.
ORCID-Profile: Sagrario Pérez-de la Cruz, Francisco Molina-Rueda, Pilar Fernández-González
Zitieren
APA
Pérez-de la Cruz, S., Molina-Rueda, F., & Fernández-González, P. (2026). Reliability of Markerless 2D Video Analysis for Calculating Gait Joint Angles in Uncontrolled Environments. Sensors. https://doi.org/10.3390/s26196229
Vancouver
Pérez-de la Cruz S, Molina-Rueda F, Fernández-González P. Reliability of Markerless 2D Video Analysis for Calculating Gait Joint Angles in Uncontrolled Environments. Sensors. 2026. doi:10.3390/s26196229
BibTeX
@article{PrezdelaCruz2026,
author = {Pérez-de la Cruz, Sagrario and Molina-Rueda, Francisco and Fernández-González, Pilar},
title = {Reliability of Markerless 2D Video Analysis for Calculating Gait Joint Angles in Uncontrolled Environments},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26196229}
}
EUVIMED