Use of the universal scan template to achieve a predictable optical impression: Preliminary data of a case series study in complete edentulous patients
Clinical Implant Dentistry and Related Research · 2024
DOI: 10.1111/cid.13292 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2024. Verfasst von Veronica Campana und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milano, Italy. Hauptthemen laut MEDLINE: Mouth, Edentulous, Dental Implants. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Full‐arch IOS scan of edentulous areas rehabilitated with dental implants is nowadays still described as an unpredictable procedure. To improve the accuracy, a universal scan template (UST®) is proposed in this article. The clinician can easily assemble the template with a mechanical coupling, by matching the scan bodies with objects of known dimension characterized by specific markers. The UST® facilitates the scanning of an entire arch on scan bodies, reducing the learning curve, simplifying acquisition movements, shortening the scanning time, and drastically reducing the risk of distortions and aberrations of the scans. Materials and Methods In a case series study on 12 patients, the improvement in the accuracy of the scans with UST® was validated by comparing the STL files derived from scans with and without the guide in place. A titanium bar was produced from each optical impression.
Results
The bars obtained from the optical impressions taken without UST® were found to be nonpassive in the mouth in the majority of the cases. On the contrary with the use of UST® we obtained 12 passive prosthetic rehabilitations.
Conclusions
The proposed solution may represent a valid method to improve the predictability of full arch optical impressions on implants.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milano, Italy.
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.
- Politecnico di Milano, Milan, Italy.
- Private Practice, Mariano Comense, Italy.
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
- Department of Implantology and Oral Rehabilitation, Dental Clinic, IRCCS Istituto Ortopedico Galeazzi, Milano, Italy.
ORCID-Profile: Massimo Del Fabbro
Zitieren
APA
Campana, V., Papa, A., Silvetti, M. A., Del Fabbro, M., & Testori, T. (2024). Use of the universal scan template to achieve a predictable optical impression: Preliminary data of a case series study in complete edentulous patients. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.13292
Vancouver
Campana V, Papa A, Silvetti MA, Del Fabbro M, Testori T. Use of the universal scan template to achieve a predictable optical impression: Preliminary data of a case series study in complete edentulous patients. Clinical Implant Dentistry and Related Research. 2024. doi:10.1111/cid.13292
BibTeX
@article{Campana2024,
author = {Campana, Veronica and Papa, Andrea and Silvetti, Manuel Amilcare and Del Fabbro, Massimo and Testori, Tiziano},
title = {Use of the universal scan template to achieve a predictable optical impression: Preliminary data of a case series study in complete edentulous patients},
journal = {Clinical Implant Dentistry and Related Research},
year = {2024},
doi = {10.1111/cid.13292}
}
EUVIMED