EUVIMEDEUVIMED entdecken
Crossref

Compact and bench-top common-path interferometric biosensor utilizing guided mode resonance phase enhancement

Neethu Baburaj, Pankaj K Sahoo, Debashree Kar, Shital Devinder, Shereena Joseph, Thomas F Krauss, Prashant Mishra, Joby Joseph

Optics Letters · 2025

DOI: 10.1364/ol.570490 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Letters, 2025. Verfasst von Neethu Baburaj und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Interferometry, Biosensing Techniques, Serum Albumin, Bovine. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The early detection and diagnosis of diseases are of paramount importance for effective healthcare outcomes. Serum albumin is an important biomarker for many diseases. A reduction in albumin can be noted in various diseases, rendering it an important marker for assessing disease progression and treatment efficacy. To get accurate readings of these biomarker levels, we need methods that are very sensitive, reliable, quick, and non-invasive. Optical phase detection techniques exhibit high sensitivity, convenient readout strategies, and low limit of detection (LOD) in comparison to other detection methods. Here, we demonstrate a new phase detection mechanism employing a Fresnel biprism in conjunction with resonantly enhanced phase sensitivity achieved by using guided mode resonance (GMR). These elements are combined into a compact and bench-top common-path phase-detection system that can be realized with very few low-cost components. The common-path configuration effectively mitigates mechanical vibrations typically associated with two-beam interferometry used for phase detection. To demonstrate the capability of our approach, we designed and fabricated a GMR-based instrument and used it to detect bovine serum albumin (BSA) at different concentrations. The stability of the setup was instrumental in detecting BSA concentrations as low as 1 pg/mL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InterferometryBiosensing TechniquesSerum Albumin, BovineCattleAnimalsLimit of Detection

Substanzen

Serum Albumin, Bovine

Zitieren

APA

Baburaj, N., Sahoo, P. K., Kar, D., Devinder, S., Joseph, S., Krauss, T. F., Mishra, P., & Joseph, J. (2025). Compact and bench-top common-path interferometric biosensor utilizing guided mode resonance phase enhancement. Optics Letters. https://doi.org/10.1364/ol.570490

Vancouver

Baburaj N, Sahoo PK, Kar D, Devinder S, Joseph S, Krauss TF, et al. Compact and bench-top common-path interferometric biosensor utilizing guided mode resonance phase enhancement. Optics Letters. 2025. doi:10.1364/ol.570490

BibTeX
@article{Baburaj2025,
  author = {Baburaj, Neethu and Sahoo, Pankaj K and Kar, Debashree and Devinder, Shital and Joseph, Shereena and Krauss, Thomas F and Mishra, Prashant and Joseph, Joby},
  title = {Compact and bench-top common-path interferometric biosensor utilizing guided mode resonance phase enhancement},
  journal = {Optics Letters},
  year = {2025},
  doi = {10.1364/ol.570490}
}
Kostenlos starten →