EUVIMEDEUVIMED entdecken
Crossref

Ligand-Involved Chemiluminescence Using Gold Nanoclusters: Mechanistic Elucidation and Its Application for Ultrasensitive Trypsin Biosensing

Tongtong Zhai, Jing Li iD, Erkang Wang iD

Analytical Chemistry · 23.06.2026 · 98 (24) · 18052-18062

DOI: 10.1021/acs.analchem.6c01812 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 08.06.2026. Verfasst von Tongtong Zhai und 2 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, …. Hauptthemen laut MEDLINE: Gold, Metal Nanoparticles, Biosensing Techniques, Trypsin. Die Arbeit nennt 41 Literaturangaben. Gefördert von: Natural Science Foundation of Jilin Province, Major Scientific and Technological Innovation Project of Shandong Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Traditional molecular chemiluminescence (CL) often suffers from low photon yields because each event typically produces limited emission. Self-amplification using nanomaterial probes with high-density ligands can increase photon output per luminophore; however, widely used CdTe nanocrystals and perovskites remain constrained by poor stability and biocompatibility. Herein, we report a protein-engineered bovine serum albumin-stabilized gold nanocluster (BSA-Au NCs) CL probe that delivers high-intensity emission while addressing these limitations. The CL intensity depends on BSA concentration and the triggering oxidant, and structural analyses indicate that a more loosely folded secondary structure favors stronger CL. Notably, NaClO oxidizes the BSA ligand shell and provides sufficient energy to excite Au NCs, producing an ∼800-fold higher CL signal than H 2 O 2 at the same concentration. The red-shifted CL spectrum relative to photoluminescence, together with X-ray photoelectron spectroscopy, supports a ligand-involved emission mechanism, which is further validated by BSA-specific recognition experiments. Leveraging ligand-shell disruption, we construct a signal-off CL assay for ultrasensitive trypsin detection with a linear range of 0.01–500 μg/mL and a detection limit of 3.3 ng/mL (S/N = 3). This work provides a robust trypsin sensing platform and mechanistic insight into ligand-involved CL in BSA-Au NCs, enabling the rational design of functional Au nanocluster-based luminescent materials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GoldMetal NanoparticlesBiosensing TechniquesTrypsinLuminescent MeasurementsLigandsSerum Albumin, BovineAnimalsCattleLuminescenceLimit of Detection

Substanzen

GoldLigandsTrypsinSerum Albumin, Bovine

Autor:innen und Institutionen

  • State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China.
  • College of Chemistry, Jilin University, Changchun, Jilin 130012, China.

ORCID-Profile: Jing Li, Erkang Wang

Förderung

  • Natural Science Foundation of Jilin Province
  • Major Scientific and Technological Innovation Project of Shandong Province
  • National Natural Science Foundation of China

Zitieren

APA

Zhai, T., Li, J., & Wang, E. (2026). Ligand-Involved Chemiluminescence Using Gold Nanoclusters: Mechanistic Elucidation and Its Application for Ultrasensitive Trypsin Biosensing. Analytical Chemistry, 98(24), 18052-18062. https://doi.org/10.1021/acs.analchem.6c01812

Vancouver

Zhai T, Li J, Wang E. Ligand-Involved Chemiluminescence Using Gold Nanoclusters: Mechanistic Elucidation and Its Application for Ultrasensitive Trypsin Biosensing. Analytical Chemistry. 2026;98(24):18052-18062. doi:10.1021/acs.analchem.6c01812

BibTeX
@article{Zhai2026,
  author = {Zhai, Tongtong and Li, Jing and Wang, Erkang},
  title = {Ligand-Involved Chemiluminescence Using Gold Nanoclusters: Mechanistic Elucidation and Its Application for Ultrasensitive Trypsin Biosensing},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {24},
  pages = {18052--18062},
  doi = {10.1021/acs.analchem.6c01812}
}
Kostenlos starten →