Self-enhanced biohybrid frameworks as novel ECL emitters for sensitive detection of CA15-3
Biosensors and Bioelectronics · 2025-12 · 290 · 118013
DOI: 10.1016/j.bios.2025.118013 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-12. Verfasst von Lipeng Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Ji…. Hauptthemen laut MEDLINE: Biosensing Techniques, Luminescent Measurements, Mucin-1, Breast Neoplasms. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Early screening for breast cancer can be effective in reducing cancer mortality; therefore, accurate detection of breast cancer marker carbohydrate antigen 15-3 (CA15-3) is of great importance. In this study, a highly sensitive sandwich-type electrochemiluminescence (ECL) biosensor based on an electron transfer quenching mechanism was developed for the ultrasensitive detection of the CA15-3. The self-assembled biohybrid framework through hydrogen bonding between the amino groups (-NH2) of bovine serum albumin (BSA) and the carboxylic acid groups (-COOH) of perylene tetracarboxylic acid (PTCA) was used as a luminophore. The aggregation-caused quenching (ACQ) effect was effectively suppressed by framework spatial arrangement preventing PTCA aggregation and enhancing ECL emission. Simultaneously, introduction of Au NCs with BSA as a protective ligand catalyzed the production of more SO4•- radicals from S2O82- to enhance ECL emission intensity. Cu2O@MnO2 with matched energy level can be used as an electron transfer quencher to construct sandwich-type ECL biosensors. ECL signals was quenched by target response via the electron transfer (ET) pathway. The sensor achieves sensitive detection of CA15-3 under optimal conditions with a wide response range (0.001-100 U/mL) and a low limit of detection (LOD) (0.00014 U/mL), and has sufficient practical analytical performance. This study provides a high-precision analytical platform for the sensitive detection of CA15-3 and offers more possibilities for the development of ECL systems based on novel biohybridisation frameworks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan Un…
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China. Electronic address: chm_mahm@ujn.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Liu, L., Chen, W., Yin, L., Sun, X., Li, Y., Wei, Q., & Ma, H. (2025). Self-enhanced biohybrid frameworks as novel ECL emitters for sensitive detection of CA15-3. Biosensors and Bioelectronics, 290, 118013. https://doi.org/10.1016/j.bios.2025.118013
Vancouver
Liu L, Chen W, Yin L, Sun X, Li Y, Wei Q, et al. Self-enhanced biohybrid frameworks as novel ECL emitters for sensitive detection of CA15-3. Biosensors and Bioelectronics. 2025;290:118013. doi:10.1016/j.bios.2025.118013
BibTeX
@article{Liu2025,
author = {Liu, Lipeng and Chen, Wenze and Yin, Lu and Sun, Xiaojun and Li, Yan and Wei, Qin and Ma, Hongmin},
title = {Self-enhanced biohybrid frameworks as novel ECL emitters for sensitive detection of CA15-3},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {290},
pages = {118013},
doi = {10.1016/j.bios.2025.118013}
}
EUVIMED