Real-time breath gas analysis of methane using a multipass cell-based near-infrared gas sensor
Biomedical Optics Express · 01.07.2024 · 15 (7) · 4207
DOI: 10.1364/boe.528923 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 10.06.2024. Verfasst von Rong Kong und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Quantum Studies, Applied Optics Beijing Area Major Laboratory, Department of Physics, Beijing Normal University , Beijing 100875,…. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Beijing Define Technology Co., Ltd..
Abstract (Originalsprache)
We demonstrated a near-infrared exhaled breath sensor for real-time methane measurements by using tunable diode laser absorption spectroscopy (TDLAS), which can enable the noninvasive diagnosis of intestinal tract problems. The core component of the near-infrared TDLAS sensor is a two-mirror-based multipass cell with nine-circle patterns. An optical path length of 23.4 m was achieved in a volume of 233.3 cm 3 , which effectively improved the detection sensitivity and shortened the gas exchange time. The minimum detection limit was 0.37 ppm by applying wavelength modulation spectroscopy, which was 12.4 times greater than that of direct absorption spectroscopy. In addition, combined with wavelength modulation spectroscopy, the two-mirror-based multipass cell enabled sub-second gas exchange time of 0.6 s. Methane breath experiments were conducted with six volunteers, and the real-time measurement results and concentrations at the end of exhalation were analyzed. This study demonstrates that the developed sensor has high sensitivity, high selectivity, and fast response for breath methane measurements and has promising potential for noninvasive, real-time, and point-of-care disease diagnosis in clinical applications.
Autor:innen und Institutionen
- Center for Advanced Quantum Studies, Applied Optics Beijing Area Major Laboratory, Department of Physics, Beijing Normal University , Beijing 100875, China.
- Key Laboratory of Multiscale Spin Physics (Ministry of Education), Beijing Normal University, Beijing 100875, China.
Förderung
- Beijing Define Technology Co., Ltd.
Zitieren
APA
Kong, R., Huang, J., Liu, P., & Zhou, X. (2024). Real-time breath gas analysis of methane using a multipass cell-based near-infrared gas sensor. Biomedical Optics Express, 15(7), 4207. https://doi.org/10.1364/boe.528923
Vancouver
Kong R, Huang J, Liu P, Zhou X. Real-time breath gas analysis of methane using a multipass cell-based near-infrared gas sensor. Biomedical Optics Express. 2024;15(7):4207. doi:10.1364/boe.528923
BibTeX
@article{Kong2024,
author = {Kong, Rong and Huang, Jie and Liu, Peng and Zhou, Xin},
title = {Real-time breath gas analysis of methane using a multipass cell-based near-infrared gas sensor},
journal = {Biomedical Optics Express},
year = {2024},
volume = {15},
number = {7},
pages = {4207},
doi = {10.1364/boe.528923}
}
EUVIMED