Real-Time Mapping of Polymer Film Thickness Using Near-Infrared Hyperspectral Imaging
Applied Spectroscopy · 2025-10 · 79 (10) · 1518-1526
DOI: 10.1177/00037028251323634 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Spectroscopy, online erschienen am 13.03.2025. Verfasst von Xiaoyun Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Analytical Science, 1897 Building, The Dow Chemical Company, Midland, Michigan 48667, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
A new method based on near-infrared (NIR) hyperspectral imaging (HSI) has been developed for online polymer film thickness mapping. Traditional online methods, including X-ray, capacitance, and physical gauging (micrometers), can only determine film thickness for a point with each measurement. The NIR-HIS method allows the determination of film thickness for a line based on each image, thus enabling true real-time two-dimensional (2D) mapping of film thickness as the film translates in front of the instrument. A Specim NIR camera, 1000–2500 nm, 384 (spatial) × 288 (spatial) pixels, was used in this study for various low-density polyethylene (LDPE), and high-density polyethylene (HDPE) films. Sample thickness between μm to mm can be mapped based on the myriad NIR absorbance bands with various molar absorptivity. The 2310 nm NIR peak was found to be the most effective feature for determining film thickness over the range of polyethylene film studied in this project: 10∼100 μm. A good correlation was found between the 2310 nm absorbance and the incumbent X-ray thickness scanner results. Interference fringes were found to be a potential source of error for quantitative analysis of thin films, and a classical least squares (CLS) analysis was found to be effective in removing fringes. This method was implemented to map out film thickness in real-time in an industrial blown film process.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Analytical Science, 1897 Building, The Dow Chemical Company, Midland, Michigan 48667, USA.
- Materials Science, 1702 Building, The Dow Chemical Company, Midland, Michigan 48667, USA.
- Information Research, 400 Arcola Road, The Dow Chemical Company, Collegeville, Pennsylvania 19426, USA.
ORCID-Profile: Xiaoyun Chen, Christopher Thurber
Zitieren
APA
Chen, X., Wang, J., Thurber, C., Benedict, M., Olson, K., Marchbanks, E., Kim, H., & Bishop, M. (2025). Real-Time Mapping of Polymer Film Thickness Using Near-Infrared Hyperspectral Imaging. Applied Spectroscopy, 79(10), 1518-1526. https://doi.org/10.1177/00037028251323634
Vancouver
Chen X, Wang J, Thurber C, Benedict M, Olson K, Marchbanks E, et al. Real-Time Mapping of Polymer Film Thickness Using Near-Infrared Hyperspectral Imaging. Applied Spectroscopy. 2025;79(10):1518-1526. doi:10.1177/00037028251323634
BibTeX
@article{Chen2025,
author = {Chen, Xiaoyun and Wang, Jin and Thurber, Christopher and Benedict, Matthew and Olson, Kurt and Marchbanks, Eric and Kim, Hyunwoo and Bishop, Michael},
title = {Real-Time Mapping of Polymer Film Thickness Using Near-Infrared Hyperspectral Imaging},
journal = {Applied Spectroscopy},