Ocular radiation exposure is negligible in normal volume endourological practice
The Annals of The Royal College of Surgeons of England · 2025
DOI: 10.1308/rcsann.2024.0004 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Annals of The Royal College of Surgeons of England, 2025. Verfasst von J Peacock und 1 weiteren Autor:innen. Beteiligte Einrichtung: Cheltenham General Hospital, UK. Hauptthemen laut MEDLINE: Radiation Exposure, Occupational Exposure, Eye. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
The annual dose limit for radiation exposure to the eye has been reduced recently; the eye is widely recognised as one of the most radiosensitive tissues in the body. There is minimal good quality research as to the radiation dose that the eye receives during endourological surgery and this study aimed to address this.
Methods
A prospective study was performed over an 8-month period at a single large teaching hospital in the UK. Three index procedures were included: ureteric stent insertion, ureteroscopy (URS) and percutaneous nephrolithotomy (PCNL). Surgeons wore a dosimeter on the glabella with fluoroscopy time (FT) and dose area product (DAP) recorded for each case.
Results
A total of 404 procedures were included (247 URSs, 150 ureteric stent insertions and 7 PCNLs). Dosimeters were worn by ten surgeons. Mean FTs (URS 20.56s; ureteric stent 18.96s; PCNL 360.67s) and mean DAP (URS 100.82cGy/m 2 , ureteric stent 119.82cGy/m 2 and PCNL 1121.62cGy/m 2 ) were identified with significant intersurgeon variability. No surgeon had a total dosimeter dose >0.00mSv.
Conclusions
The International Commission on Radiological Protection recently reduced the yearly eye dose limit from 150 to 20mSv. Cataractogenesis is no longer considered a typical deterministic effect, with a threshold level below which no effect occurs. Even in higher volume centres, these annual limits are unlikely to be reached. Lead glasses may be considered for surgeons and radiologists with the highest exposure but, for the majority, ocular radiation exposure is negligible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cheltenham General Hospital, UK.
Zitieren
APA
Peacock, J., & Henderson, J. (2025). Ocular radiation exposure is negligible in normal volume endourological practice. The Annals of The Royal College of Surgeons of England. https://doi.org/10.1308/rcsann.2024.0004
Vancouver
Peacock J, Henderson J. Ocular radiation exposure is negligible in normal volume endourological practice. The Annals of The Royal College of Surgeons of England. 2025. doi:10.1308/rcsann.2024.0004
BibTeX
@article{Peacock2025,
author = {Peacock, J and Henderson, J},
title = {Ocular radiation exposure is negligible in normal volume endourological practice},
journal = {The Annals of The Royal College of Surgeons of England},
year = {2025},
doi = {10.1308/rcsann.2024.0004}
}
EUVIMED