Improving image quality with deep learning image reconstruction in double-low-dose head CT angiography compared with standard dose and adaptive statistical iterative reconstruction

Xin Huang, Wenzhe Zhao, Geliang Wang, Yiming Wang, Jianying Li, Yanshou Li, Qiang Zeng, Jianxin Guo

The British Journal of Radiology · 2023

DOI: 10.1259/bjr.20220625 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift The British Journal of Radiology, 2023. Verfasst von Xin Huang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, the First Affiliated Hospital of Xi'an Jiaotong University, Shaanxi province, China. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Deep Learning. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To demonstrate similar image quality with deep learning image reconstruction (DLIR) in reduced contrast medium (CM) and radiation dose (double-low-dose) head CT angiography (CTA), in comparison with standard-dose and adaptive statistical iterative reconstruction-Veo (ASIR-V).

Methods

A prospective study was performed in 63 patients who under head CTA using 256-slice CT. Patients were randomized into either the standard-dose group (n = 38) with 40 ml of Iopromide (370 mgI ml −1 at 4.5 ml s −1 ); or a double-low-dose group (n = 25) with CM of 25 ml at 3.0 ml s −1 . For image reconstruction, the double-low-dose group used DLIR-M and DLIR-H strength, and the standard-dose group used ASIR-V with 50% strength. The CT value and standard deviation, signal-to-noise ratio and contrast-to-noise ratio of posterior fossa, neck muscles, carotid, vertebral and middle cerebral arteries were measured. The image noise, vessel edge and structure blurring and overall image quality were assessed by using a 5-grade method. The double-low-dose group reduced CM dose by 37.5% and CT dose index by 41% compared with the standard-dose group. DLIR further reduced the standard deviation value of the middle cerebral artery and posterior fossa and provided better overall subjective image quality (p < 0.05).

Conclusion

DLIR significantly reduces image noise and provides higher overall image quality in the double-low-dose CTA. Advances in knowledge It is feasible to reduce CM dose by 37.5% and volume CT dose index by 41% with the combination of 80 kVp and DLIR in head CTA. Compared with ASIR-V, DLIR further reduces image noise and achieves better image quality with reduced contrast and radiation dose.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyDeep LearningHumansProspective StudiesTomography, X-Ray ComputedRadiation DosageImage Processing, Computer-AssistedRadiographic Image Interpretation, Computer-AssistedAlgorithms

Autor:innen und Institutionen

  • Department of Radiology, the First Affiliated Hospital of Xi'an Jiaotong University, Shaanxi province, China.
  • CT Research Center, GE Healthcare China, Beijing, China.

Zitieren

APA

Huang, X., Zhao, W., Wang, G., Wang, Y., Li, J., Li, Y., Zeng, Q., & Guo, J. (2023). Improving image quality with deep learning image reconstruction in double-low-dose head CT angiography compared with standard dose and adaptive statistical iterative reconstruction. The British Journal of Radiology. https://doi.org/10.1259/bjr.20220625

Vancouver

Huang X, Zhao W, Wang G, Wang Y, Li J, Li Y, et al. Improving image quality with deep learning image reconstruction in double-low-dose head CT angiography compared with standard dose and adaptive statistical iterative reconstruction. The British Journal of Radiology. 2023. doi:10.1259/bjr.20220625

BibTeX
@article{Huang2023,
  author = {Huang, Xin and Zhao, Wenzhe and Wang, Geliang and Wang, Yiming and Li, Jianying and Li, Yanshou and Zeng, Qiang and Guo, Jianxin},
  title = {Improving image quality with deep learning image reconstruction in double-low-dose head CT angiography compared with standard dose and adaptive statistical iterative reconstruction},
  journal = {The British Journal of Radiology},
  year = {2023},
  doi = {10.1259/bjr.20220625}
}
Kostenlos starten →