EUVIMEDEUVIMED entdecken
Crossref

Image quality with reduced radiation dose and contrast medium of cardiac computed tomography in infants with congenital heart disease using 70 KVP and DEEP-learning reconstruction with 256-detector CT

Takayuki Yoshiura iD, Takanori Masuda iD, Yukie Kobayashi, Tomohiro Kimura, Yukari Kikuhara, Yuma Yamamoto, Takayuki Oku iD, Tomoyasu Sato iD, Yoshinori Funama

Radiation Protection Dosimetry · 02.01.2026 · 202 (1) · 43-52

DOI: 10.1093/rpd/ncaf152 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 13.12.2025. Verfasst von Takayuki Yoshiura und 8 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan. Hauptthemen laut MEDLINE: Heart Defects, Congenital, Contrast Media, Deep Learning, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study compared radiation dose, vascular enhancement, and contrast-to-noise ratio (CNR) of 256-multidetector row computed tomography (MDCT) at 70 kVp with deep-learning reconstruction (DLR) to 64-MDCT at 80 kVp with ASiR of cardiac CT angiography (CCTA) in infants with congenital heart disease. The contrast medium (CM) was 266 mg/kg for the 256-MDCT group and 600 mg/kg for the 64-MDCT group. In the 256- and 64-MDCT groups, the median values were 0.45 and 0.75 mGy for adjusted volume CT dose index (P < .05) and 4.98 and 8.00 mGy-cm for dose length product (P < .05). Despite a 49% CM reduction in the 256-MDCT group, vascular enhancement and CNR showed no significant differences (P > .05). The 256-MDCT at 70 kVp with DLR can maintain vascular CT enhancement and CNR while reducing CM by 49% and radiation dose by 41% in infant CCTA, compared with 64-MDCT at 80 kVp with ASiR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Defects, CongenitalContrast MediaDeep LearningRadiographic Image Interpretation, Computer-AssistedComputed Tomography AngiographyMultidetector Computed TomographyImage Processing, Computer-AssistedHumansRadiation DosageInfantMaleFemaleInfant, NewbornTomography, X-Ray ComputedSignal-To-Noise Ratio

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan.
  • Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan.
  • Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Okayama, 701-0193, Japan.
  • Department of Medical Radiation Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan.

ORCID-Profile: Takayuki Yoshiura, Takanori Masuda, Takayuki Oku, Tomoyasu Sato

Zitieren

APA

Yoshiura, T., Masuda, T., Kobayashi, Y., Kimura, T., Kikuhara, Y., Yamamoto, Y., Oku, T., Sato, T., & Funama, Y. (2026). Image quality with reduced radiation dose and contrast medium of cardiac computed tomography in infants with congenital heart disease using 70 KVP and DEEP-learning reconstruction with 256-detector CT. Radiation Protection Dosimetry, 202(1), 43-52. https://doi.org/10.1093/rpd/ncaf152

Vancouver

Yoshiura T, Masuda T, Kobayashi Y, Kimura T, Kikuhara Y, Yamamoto Y, et al. Image quality with reduced radiation dose and contrast medium of cardiac computed tomography in infants with congenital heart disease using 70 KVP and DEEP-learning reconstruction with 256-detector CT. Radiation Protection Dosimetry. 2026;202(1):43-52. doi:10.1093/rpd/ncaf152

BibTeX
@article{Yoshiura2026,
  author = {Yoshiura, Takayuki and Masuda, Takanori and Kobayashi, Yukie and Kimura, Tomohiro and Kikuhara, Yukari and Yamamoto, Yuma and Oku, Takayuki and Sato, Tomoyasu and Funama, Yoshinori},
  title = {Image quality with reduced radiation dose and contrast medium of cardiac computed tomography in infants with congenital heart disease using 70 KVP and DEEP-learning reconstruction with 256-detector CT},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  volume = {202},
  number = {1},
  pages = {43--52},
  doi = {10.1093/rpd/ncaf152}
}
Kostenlos starten →