EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deep learning-based pseudo-CT synthesis from zero echo time MR sequences of the pelvis

Jonas M Getzmann, Eva Deininger-Czermak, Savvas Melissanidis, Falko Ensle, Sandeep S Kaushik, Florian Wiesinger, Cristina Cozzini, Luca M Sconfienza, Roman Guggenberger

Insights into Imaging · 09.08.2024 · 15 (1)

DOI: 10.1186/s13244-024-01751-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Insights into Imaging, online erschienen am 09.08.2024. Verfasst von Jonas M Getzmann und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Zurich, Switzerland. jonas.getzmann@gmail.com. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To generate pseudo-CT (pCT) images of the pelvis from zero echo time (ZTE) MR sequences and compare them to conventional CT.

Methods

Ninety-one patients were prospectively scanned with CT and MRI including ZTE sequences of the pelvis. Eleven ZTE image volumes were excluded due to implants and severe B1 field inhomogeneity. Out of the 80 data sets, 60 were used to train and update a deep learning (DL) model for pCT image synthesis from ZTE sequences while the remaining 20 cases were selected as an evaluation cohort. CT and pCT images were assessed qualitatively and quantitatively by two readers.

Results

Mean pCT ratings of qualitative parameters were good to perfect (2–3 on a 4-point scale). Overall intermodality agreement between CT and pCT was good (ICC = 0.88 (95% CI: 0.85–0.90); p < 0.001) with excellent interreader agreements for pCT (ICC = 0.91 (95% CI: 0.88–0.93); p < 0.001). Most geometrical measurements did not show any significant difference between CT and pCT measurements ( p > 0.05) with the exception of transverse pelvic diameter measurements and lateral center-edge angle measurements ( p = 0.001 and p = 0.002, respectively). Image quality and tissue differentiation in CT and pCT were similar without significant differences between CT and pCT CNRs (all p > 0.05).

Conclusions

Using a DL-based algorithm, it is possible to synthesize pCT images of the pelvis from ZTE sequences. The pCT images showed high bone depiction quality and accurate geometrical measurements compared to conventional CT. Critical relevance statement pCT images generated from MR sequences allow for high accuracy in evaluating bone without the need for radiation exposure. Radiological applications are broad and include assessment of inflammatory and degenerative bone disease or preoperative planning studies. Key Points pCT, based on DL-reconstructed ZTE MR images, may be comparable with true CT images. Overall, the intermodality agreement between CT and pCT was good with excellent interreader agreements for pCT. Geometrical measurements and tissue differentiation were similar in CT and pCT images. Graphical Abstract

Schlagwörter

Stichwörter der Autor:innen

Artificial intelligenceDeep learningMagnetic resonance imagingSynthetic computed tomographyZero echo time

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Zurich, Switzerland. jonas.getzmann@gmail.com.
  • University of Zurich (UZH), Zurich, Switzerland. jonas.getzmann@gmail.com.
  • Unit of Diagnostic and Interventional Radiology, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy. jonas.getzmann@gmail.com.
  • Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Zurich, Switzerland.
  • University of Zurich (UZH), Zurich, Switzerland.
  • Institute of Forensic Medicine, University of Zurich (UZH), Zurich, Switzerland.

Zitieren

APA

Getzmann, J. M., Deininger-Czermak, E., Melissanidis, S., Ensle, F., Kaushik, S. S., Wiesinger, F., Cozzini, C., Sconfienza, L. M., & Guggenberger, R. (2024). Deep learning-based pseudo-CT synthesis from zero echo time MR sequences of the pelvis. Insights into Imaging, 15(1). https://doi.org/10.1186/s13244-024-01751-3

Vancouver

Getzmann JM, Deininger-Czermak E, Melissanidis S, Ensle F, Kaushik SS, Wiesinger F, et al. Deep learning-based pseudo-CT synthesis from zero echo time MR sequences of the pelvis. Insights into Imaging. 2024;15(1). doi:10.1186/s13244-024-01751-3

BibTeX
@article{Getzmann2024,
  author = {Getzmann, Jonas M and Deininger-Czermak, Eva and Melissanidis, Savvas and Ensle, Falko and Kaushik, Sandeep S and Wiesinger, Florian and Cozzini, Cristina and Sconfienza, Luca M and Guggenberger, Roman},
  title = {Deep learning-based pseudo-CT synthesis from zero echo time MR sequences of the pelvis},
  journal = {Insights into Imaging},
  year = {2024},
  volume = {15},
  number = {1},
  doi = {10.1186/s13244-024-01751-3}
}
Kostenlos starten →