Lung Density Measurement in Fontan Patients Using Zero Echo Time Sequences

Alessia Callegari, Konstantinos Zeimpekis, Barbara E U Burkhardt, Emanuela R Valsangiacomo Buechel, Fraser M Callaghan, Jakob Usemann, Martin Hersberger, Christian J Kellenberger, Julia Geiger

Pediatric Cardiology · 2026-02 · 47 (2) · 718-728

DOI: 10.1007/s00246-025-03825-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Cardiology, online erschienen am 18.03.2025. Verfasst von Alessia Callegari und 8 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland. alessia.callegari@kispi.uzh.ch. Hauptthemen laut MEDLINE: Fontan Procedure, Heart Defects, Congenital, Lung, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Children’s Research Center (CRC) of the University Children’s Hospital of Zurich, University of Zurich.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pulmonary complications are known to occur in patients after Fontan palliation. Cardiac MRI is performed in the follow-up of Fontan patients to assess single ventricular function, hemodynamics and potential collateral flow. To date, pulmonary function tests have been used to detect functional lung impairment, but lung MRI has not been integrated into imaging follow-up. In this study, we measured lung-to-background ratio (LBR) on zero echo time (ZTE) MRI sequences in 32 children with Fontan palliation. Patients were divided into 2 groups: LBR > 1.5 and < 1.5 and assessed for associations between LBR and ventricular function, fibrosis, hemodynamics as well as biomarkers, spirometry and previous catheter results. We observed significantly increased extracellular volume (ECV) and decreased tissue inhibitor of metalloproteinase 1 (TIMP-1), soluble suppression of tumorigenicity 2 (sST-2) and a trend towards decreased growth differentiation factor 15 (GDF-15) as well as decreased albumin and prothrombin time values in patients with elevated LBR, whereas the other cardiovascular and pulmonary parameters did not differ significantly. Moreover, patients with LBR > 1.5 had a history of increased pulmonary arterial pressure prior to the Fontan and Glenn procedures and interventional veno-venous collateral embolization. Monitoring lung density with ZTE MRI sequences may be helpful in the diagnostic workup to assess the outcome of patients after Fontan procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fontan ProcedureHeart Defects, CongenitalLungMagnetic Resonance ImagingHumansMaleFemaleChildChild, PreschoolAdolescentRespiratory Function TestsBiomarkers

Stichwörter der Autor:innen

BiomarkersFontan circulationLung densityMagnetic resonance imagingSingle ventricle

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland. alessia.callegari@kispi.uzh.ch.
  • Children´s Research Center, University Children's Hospital Zurich, Zurich, Switzerland. alessia.callegari@kispi.uzh.ch.
  • Pediatric Heart Centre, Division of Pediatric Cardiology, University Children's Hospital Zurich, Lenggstrasse 30, CH-8008, Zurich, Switzerland. alessia.callegari@kispi.uzh.ch.
  • Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.
  • Children´s Research Center, University Children's Hospital Zurich, Zurich, Switzerland.

Förderung

  • Children’s Research Center (CRC) of the University Children’s Hospital of Zurich
  • University of Zurich

Zitieren

APA

Callegari, A., Zeimpekis, K., Burkhardt, B. E. U., Buechel, E. R. V., Callaghan, F. M., Usemann, J., Hersberger, M., Kellenberger, C. J., & Geiger, J. (2026). Lung Density Measurement in Fontan Patients Using Zero Echo Time Sequences. Pediatric Cardiology, 47(2), 718-728. https://doi.org/10.1007/s00246-025-03825-5

Vancouver

Callegari A, Zeimpekis K, Burkhardt BEU, Buechel ERV, Callaghan FM, Usemann J, et al. Lung Density Measurement in Fontan Patients Using Zero Echo Time Sequences. Pediatric Cardiology. 2026;47(2):718-728. doi:10.1007/s00246-025-03825-5

BibTeX
@article{Callegari2026,
  author = {Callegari, Alessia and Zeimpekis, Konstantinos and Burkhardt, Barbara E U and Buechel, Emanuela R Valsangiacomo and Callaghan, Fraser M and Usemann, Jakob and Hersberger, Martin and Kellenberger, Christian J and Geiger, Julia},
  title = {Lung Density Measurement in Fontan Patients Using Zero Echo Time Sequences},
  journal = {Pediatric Cardiology},
  year = {2026},
  volume = {47},
  number = {2},
  pages = {718--728},
  doi = {10.1007/s00246-025-03825-5}
}
Kostenlos starten →