EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An institutional experience of a scripting‐driven automation of the emergent palliative radiotherapy workflow

Shadab Momin, Eduard Schreibmann, Justin Roper, Beth Ghavidel, Maxine Washington, Oluwatosin Kayode, Pretesh Patel, Ashish Patel, Hania Al-Hallaq, Yulia Lyatskaya

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70814 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Shadab Momin und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Workflow, Radiotherapy Planning, Computer-Assisted, Palliative Care, Cone-Beam Computed Tomography. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Emergency palliative radiotherapy is often delivered under time‐constrained and high‐stress conditions, frequently bypassing conventional computed tomography (CT) simulation and relying on nonstandard workflows. These factors increase variability and the potential for error.

Purpose

This work describes the development, implementation, and early clinical evaluation of a simulation‐free, cone‐beam CT (CBCT) based emergency radiotherapy workflow that leverages treatment planning system (TPS) scripting to standardize and automate deterministic steps while preserving clinical oversight.

Methods

An ESAPI scripting‐driven emergency workflow was developed within the TPS to automate prescription handling, plan generation, beam configuration, dose calculation, and setup preparation using CBCT images. Safety checks were implemented in the form of prompts with the appropriate actions required. Alternatively, manual input was retained for image verification and treatment field borders definition. The workflow was implemented across multiple clinical sites within a single healthcare system and evaluated through dosimetric comparison of CT‐ and CBCT‐based planning. Metric parameters such as workflow time, reductions in manual interactions, and pre‐ and post‐training survey outcomes of automated 3D workflow were compared to the same parameters of the conventional 2D workflow.

Results

The automated workflow successfully generated clinically acceptable emergency treatment plans with minimal manual input. CBCT‐based dose calculations demonstrated agreement with CT‐based planning within 2.5% when heterogeneity corrections were enabled and within 4.7% when disabled. Automation eliminated 33 manual data entry steps present in the 2D workflow and enabled treatment delivery with average on‐table time of approximately an hour. Survey results demonstrated strong staff support for automation, with over 90% anticipating improvement prior to training and 100% reporting perceived improvement following training. Staff comfort and confidence improved post‐training, and concerns regarding workflow clarity and safety decreased.

Conclusions

A scripting‐based, simulation‐free emergency radiotherapy workflow was developed for safe and standardized palliative treatments while maintaining established clinical safeguards. By automating deterministic planning tasks and preserving human oversight for clinical decision‐making, the proposed approach improves consistency and staff confidence and has potential to improve safety and accuracy of palliative treatments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WorkflowRadiotherapy Planning, Computer-AssistedPalliative CareCone-Beam Computed TomographyNeoplasmsHumansRadiotherapy DosageAutomationRadiotherapy, Intensity-ModulatedOrgans at Risk

Stichwörter der Autor:innen

CBCT‐based radiation treatment planningemergency palliative radiotherapysimulation‐free workflowtreatment planning system scriptingworkflow automation

Autor:innen und Institutionen

  • Department of Radiation Oncology, Emory University, Atlanta, Georgia, USA.

Zitieren

APA

Momin, S., Schreibmann, E., Roper, J., Ghavidel, B., Washington, M., Kayode, O., Patel, P., Patel, A., Al-Hallaq, H., & Lyatskaya, Y. (2026). An institutional experience of a scripting‐driven automation of the emergent palliative radiotherapy workflow. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70814

Vancouver

Momin S, Schreibmann E, Roper J, Ghavidel B, Washington M, Kayode O, et al. An institutional experience of a scripting‐driven automation of the emergent palliative radiotherapy workflow. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70814

BibTeX
@article{Momin2026,
  author = {Momin, Shadab and Schreibmann, Eduard and Roper, Justin and Ghavidel, Beth and Washington, Maxine and Kayode, Oluwatosin and Patel, Pretesh and Patel, Ashish and Al-Hallaq, Hania and Lyatskaya, Yulia},
  title = {An institutional experience of a scripting‐driven automation of the emergent palliative radiotherapy workflow},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70814}
}