EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The influence of prosthetic suspension on gait and cortical modulations is persons with a transfemoral amputation: socket-suspended versus bone-anchored prosthesis

Vera Kooiman, Joris van der Cruijsen, Ruud Leijendekkers, Nico Verdonschot, Teodoro Solis-Escalante, Vivian Weerdesteyn

Journal of NeuroEngineering and Rehabilitation · 2024

DOI: 10.1186/s12984-024-01331-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of NeuroEngineering and Rehabilitation, 2024. Verfasst von Vera Kooiman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedic Research Laboratory, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands. Vera.Kooiman@radboudumc.nl. Hauptthemen laut MEDLINE: Bone-Anchored Prosthesis, Amputees, Artificial Limbs. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020, Nederlandse Organisatie voor Wetenschappelijk Onderzoek.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Persons with a transfemoral amputation (TFA) often experience difficulties in daily-life ambulation, including an asymmetrical and less stable gait pattern and a greater cognitive demand of walking. However, it remains unclear whether this is effected by the prosthetic suspension, as eliminating the non-rigid prosthetic connection may influence stability and cortical activity during walking. Spatiotemporal and stability-related gait parameters, as well as cortical activity during walking, were evaluated between highly active individuals (MFC-level K3-4) with a TFA and able-bodied (AB) persons, and between persons with a bone-anchored prosthesis (BAP) and those with a socket-suspended prosthesis (SSP).

Methods

18 AB persons and 20 persons with a unilateral TFA (10 BAP-users, 10 SSP-users) walked on a treadmill at their preferred speed. Spatiotemporal and margin of stability parameters were extracted from three-dimensional movement recordings. In addition, 126-channel electroencephalogram (EEG) was recorded. Brain-related activity from several cortical areas was isolated using independent component analysis. Source-level data were divided into gait cycles and subjected to time–frequency analysis to determine gait-cycle dependent modulations of cortical activity.

Results

Persons with TFA walked with smaller and wider steps and with greater variability in mediolateral foot placement than AB subjects; no significant differences were found between BAP- and SSP-users. The EEG analysis yielded four cortical clusters in frontal, central (both hemispheres), and parietal areas. No statistically significant between-group differences were found in the mean power over the entire gait cycle. The event-related spectral perturbation maps revealed differences in power modulations (theta, alpha, and beta bands) between TFA and AB groups, and between BAP- and SSP-users, with largest differences observed around heel strike of either leg.

Conclusions

The anticipated differences in gait parameters in persons with TFA were confirmed, however no significant effect of the fixed suspension of a BAP was found. The preliminary EEG findings may indicate more active monitoring and control of stability in persons with TFA, which appeared to be timed differently in SSP than in BAP-users. Future studies may focus on walking tasks that challenge stability to further investigate differences related to prosthetic suspension.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone-Anchored ProsthesisAmputeesArtificial LimbsHumansGaitAmputation, SurgicalWalkingBiomechanical PhenomenaProsthesis Design

Stichwörter der Autor:innen

AmputeeCorticalEEGGaitOsseointegrationProsthesisSocketStability

Autor:innen und Institutionen

  • Orthopedic Research Laboratory, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands. Vera.Kooiman@radboudumc.nl.
  • Department of Rehabilitation, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands. Vera.Kooiman@radboudumc.nl.
  • Department of Rehabilitation, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
  • Orthopedic Research Laboratory, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
  • Radboud Institute for Health Sciences, IQ Healthcare, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
  • Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, P.O. Box 217, 7500 AE, Enschede, The Netherlands.

Förderung

  • Horizon 2020
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Zitieren

APA

Kooiman, V., van der Cruijsen, J., Leijendekkers, R., Verdonschot, N., Solis-Escalante, T., & Weerdesteyn, V. (2024). The influence of prosthetic suspension on gait and cortical modulations is persons with a transfemoral amputation: socket-suspended versus bone-anchored prosthesis. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/s12984-024-01331-y

Vancouver

Kooiman V, van der Cruijsen J, Leijendekkers R, Verdonschot N, Solis-Escalante T, Weerdesteyn V. The influence of prosthetic suspension on gait and cortical modulations is persons with a transfemoral amputation: socket-suspended versus bone-anchored prosthesis. Journal of NeuroEngineering and Rehabilitation. 2024. doi:10.1186/s12984-024-01331-y

BibTeX
@article{Kooiman2024,
  author = {Kooiman, Vera and van der Cruijsen, Joris and Leijendekkers, Ruud and Verdonschot, Nico and Solis-Escalante, Teodoro and Weerdesteyn, Vivian},
  title = {The influence of prosthetic suspension on gait and cortical modulations is persons with a transfemoral amputation: socket-suspended versus bone-anchored prosthesis},
  journal = {Journal of NeuroEngineering and Rehabilitation},
  year = {2024},
  doi = {10.1186/s12984-024-01331-y}
}
Kostenlos starten →