Walking ability of individuals fitted with transfemoral bone-anchored prostheses: A comparative study of gait parameters
Clinical Rehabilitation · 2023
DOI: 10.1177/02692155231183779 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Rehabilitation, 2023. Verfasst von Simone Ranaldi und 6 weiteren Autor:innen. Beteiligte Einrichtung: BioLab³ - Engineering Department, Roma TRE University, Rome, Lazio, Italy. Hauptthemen laut MEDLINE: Bone-Anchored Prosthesis, Amputees, Artificial Limbs. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
This study presents the walking abilities of participants fitted with transfemoral bone-anchored prostheses using a total of 14 gait parameters.
Design
Two-centre retrospective cross-sectional comparative study.
Setting
Research facilities equipped with tridimensional motion capture systems.
Participants
Two control arms included eight able-bodied participants arm (54 ± 9 years, 1.75 ± 0.07 m, 76 ± 7 kg) and nine participants fitted with transfemoral socket-suspended prostheses arm (59 ± 9 years, 1.73 ± 0.07 m, 80 ± 16 kg). The intervention arm included nine participants fitted with transfemoral bone-anchored prostheses arm (51 ± 13 years, 1.78 ± 0.09 m, 87.3 ± 16.1 kg).
Intervention
Fitting of transfemoral bone-anchored prostheses. Main measures Comparisons were performed for two spatio-temporal, three spatial and nine temporal gait parameters.
Results
The cadence and speed of walking were 107 ± 6 steps/min and 1.23 ± 0.19 m/s for the able-bodied participants arm, 88 ± 7 steps/min and 0.87 ± 0.17 m/s for the socket-suspended prosthesis arm, and 96 ± 6 steps/min and 1.03 ± 0.17 m/s for bone-anchored prosthesis arm, respectively. Able-bodied participants and bone-anchored prosthesis arms were comparable in age, height, and body mass index as well as cadence and speed of walking, but the able-bodied participant arm showed a swing phase 31% shorter. Bone-anchored and socket-suspended prostheses arms were comparable for age, height, mass, and body mass index as well as cadence and speed of walking, but the bone-anchored prosthesis arm showed a step width and duration of double support in seconds 65% and 41% shorter, respectively.
Conclusions
Bone-anchored and socket-suspended prostheses restored equally well the gait parameters at a self-selected speed. This benchmark data provides new insights into the walking ability of individuals using transfemoral bionics bone-anchored prostheses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- BioLab³ - Engineering Department, Roma TRE University, Rome, Lazio, Italy.
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR T_9406, Lyon, France.
- Department of Engineering, University of Messina, Messina, Sicilia, Italy.
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Southport, QLD, Australia.
- YourResearchProject, Red Hill, QLD, Australia.
ORCID-Profile: Laurent Frossard
Zitieren
APA
Ranaldi, S., Naaim, A., Marchis, C., Robert, T., Dumas, R., Conforto, S., & Frossard, L. (2023). Walking ability of individuals fitted with transfemoral bone-anchored prostheses: A comparative study of gait parameters. Clinical Rehabilitation. https://doi.org/10.1177/02692155231183779
Vancouver
Ranaldi S, Naaim A, Marchis C, Robert T, Dumas R, Conforto S, et al. Walking ability of individuals fitted with transfemoral bone-anchored prostheses: A comparative study of gait parameters. Clinical Rehabilitation. 2023. doi:10.1177/02692155231183779
BibTeX
@article{Ranaldi2023,
author = {Ranaldi, Simone and Naaim, Alexandre and Marchis, Cristiano De and Robert, Thomas and Dumas, Raphael and Conforto, Silvia and Frossard, Laurent},
title = {Walking ability of individuals fitted with transfemoral bone-anchored prostheses: A comparative study of gait parameters},
journal = {Clinical Rehabilitation},
year = {2023},
doi = {10.1177/02692155231183779}
}
EUVIMED