Kontrollierte klinische Studie in der Zeitschrift BMC Oral Health, 2024. Verfasst von Paola Herrera-Pérez und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of the Basque Country (UPV/EHU), Biscay, Spain. Hauptthemen laut MEDLINE: Dental Implants, Titanium. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Rehabilitation of the anterior area when the mesio-distal space is reduced is a challenge for the clinician, due to the patient’s anatomical limitations and aesthetic requirements. Narrow Diameter Implants (NDI) are an option of treatment when the standard diameter implant is not possible, but the evidence is scarce. This prospective clinical study aims to analyze the formation of the tooth-implant papilla between the implant and the adjacent natural tooth in the maxillary lateral incisors and mandibular incisors.
Methods
A total of 40 patients treated with NDI, of titanium-zirconium (Ti-Zr) alloy i.e., 2.9 mm Test Group (TG) and 3.3 mm Control Group (CG), were included. The mesiodistal distance between the adjacent natural teeth was used for implant selection, maintaining 1.5 mm between the fixation and the adjacent tooth. Clinical assessment was performed by a clinical examiner at 6 and 12 months after the final prosthesis. The primary variable was the Jemt Papillary Index. Also, implant survival rate (SR), complications, Implant Stability Quotient (ISQ), and patient-reported outcomes measures (PROMs) such as aesthetics, chewing, phonation, comfort, and self-esteem were analyzed.
Results
A significant amount of papilla filling was observed concerning the baseline, with a trend towards more formation of the papilla in the TG, with a JPI score of 3. No significant differences were observed between the two groups regarding implant SR, clinical parameters, and complications. In terms of PROMs, a higher satisfaction in the TG was observed, with significant intergroup differences for aesthetics, comfort, self-esteem, and primary stability ISQ (TG: 59.05 (SD: 5.4) vs. CG: 51.55 (SD: 5.7)).
Conclusions
The 2.9 mm diameter Ti-Zr implants achieved a formation of papilla similar to 3.3 mm implants in the anterior region at 12 months of follow-up after the final prosthetic restoration. The use of Ti-Zr implants with a diameter of 2.9 mm to rehabilitate single teeth in areas of the anterior region, where the mesiodistal distance is limited, showed favorable clinical results and a high degree of satisfaction during 1 year of observation similar to 3.3 mm dental implants.
Trial registration
This study was retrospectively registered in ClinicalTrials.gov with the number NCT05642520, dated 18/11/2022.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University of the Basque Country (UPV/EHU), Biscay, Spain.
- Research Group: GIU21/042Department of StomatologyFaculty of Medicine and Nursing, University of the Basque Country (UPV/EHU), Barrio Sarriena S/N, 48940, Leioa, Biscay, Spain. anamaria.garciad@ehu.eus.
- International University of Catalunya, Barcelona, Spain.
- Department of Stomatology, University of the Basque Country (UPV/EHU), Biscay, Spain.
- Research Group: GIU21/042, Department of Nursery I, University of the Basque Country (UPV/EHU), Biscay, Spain.
- Research Group: GIU21/042Department of StomatologyFaculty of Medicine and Nursing, University of the Basque Country (UPV/EHU), Barrio Sarriena S/N, 48940, Leioa, Biscay, Spain.
Zitieren
APA
Herrera-Pérez, P., García-De-La-Fuente, A. M., Andia-Larrea, E., Marichalar-Mendia, X., Aguirre-Urizar, J. M., & Aguirre-Zorzano, L. A. (2024). Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study. BMC Oral Health. https://doi.org/10.1186/s12903-024-04075-2
Vancouver
Herrera-Pérez P, García-De-La-Fuente AM, Andia-Larrea E, Marichalar-Mendia X, Aguirre-Urizar JM, Aguirre-Zorzano LA. Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study. BMC Oral Health. 2024. doi:10.1186/s12903-024-04075-2
BibTeX
@article{HerreraPrez2024,
author = {Herrera-Pérez, Paola and García-De-La-Fuente, Ana María and Andia-Larrea, Eztizen and Marichalar-Mendia, Xabier and Aguirre-Urizar, José Manuel and Aguirre-Zorzano, Luis Antonio},
title = {Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study},
journal = {BMC Oral Health},
year = {2024},
doi = {10.1186/s12903-024-04075-2}
}
EUVIMED