EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Radiographic Peri‐Implant Bone Changes in Osteoporotic Women Treated With a Ti‐Zr, Bone Level Tapered Implant With a Hydrophilic Surface: A 12‐Month Prospective Case‐Series

Calciolari Elena iD, Mardas Nikos iD, Palaska Iro, Tagliaferri Sara, Donos Nikolaos iD

Clinical Oral Implants Research · 2025-10 · 36 (10) · 1234-1247

DOI: 10.1111/clr.14469 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 08.07.2025. Verfasst von Calciolari Elena und 4 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London, London, UK. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Dental Implants, Single-Tooth, Dental Prosthesis Design, Osteoporosis, Postmenopausal. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 90 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institut Straumann.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study assessed 12‐month post‐loading 3D peri‐implant radiographic bone changes in osteoporotic women receiving a single titanium‐zirconium bone‐level tapered dental implant with a hydrophilic surface. Materials and Methods This was a prospective case series involving 18 post‐menopausal osteoporotic women in need of a single dental implant. A standardized CBCT scan was performed after implant placement and at 12 months post‐loading to assess peri‐implant bone changes. The Implant Stability Quotient (ISQ) was recorded after implant placement, at implant impression, loading, and 12 months post‐loading. Peri‐implant clinical parameters were recorded at 6 and 12 months post‐loading and during the last visit implant survival and success were also evaluated.

Results

Seventeen patients completed all study visits, and implant placement was uneventful for all participants. A statistically significant difference (reduction) from implant placement to 12 months post‐loading was observed in terms of radiographic buccal bone width and palatal/lingual width (ΔBw‐0: 0.53 mm, p < 0.001 and ΔPw‐0: 0.47 mm, p = 0.006), as well as in terms of vertical distance between the implant shoulder and the first bone to implant contact on the buccal and palatal/lingual aspect (ΔBICb: −0.26 mm, p = 0.005 and ΔBICp: −0.46 mm, p = 0.018). ISQ increased during osseointegration, and a high implant survival (100%) and success rate (from 81.3% to 100% based on 3 different sets of criteria) were recorded at 12 months post‐loading.

Conclusion

In this case series, osteoporotic patients treated with single titanium‐zirconium implants showed high survival rates, predictable 12‐month implant outcomes, and physiologic peri‐implant bone remodelling. Trial Registration: NCT02884401

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Implantation, EndosseousDental Implants, Single-ToothDental Prosthesis DesignOsteoporosis, PostmenopausalAgedFemaleHumansMiddle AgedCone-Beam Computed TomographyDental ImplantsHydrophobic and Hydrophilic InteractionsProspective StudiesSurface PropertiesTitaniumTreatment OutcomeZirconium

Stichwörter der Autor:innen

bone regenerationdental implantationosseointegrationosteoporosispost‐menopausal

Substanzen

Dental ImplantsTitaniumZirconium

Autor:innen und Institutionen

  • Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London, London, UK.
  • Department of Medicine and Surgery, University of Parma, Parma, Italy.

ORCID-Profile: Calciolari Elena, Mardas Nikos, Donos Nikolaos

Förderung

  • Institut Straumann

Zitieren

APA

Elena, C., Nikos, M., Iro, P., Sara, T., & Nikolaos, D. (2025). Radiographic Peri‐Implant Bone Changes in Osteoporotic Women Treated With a Ti‐Zr, Bone Level Tapered Implant With a Hydrophilic Surface: A 12‐Month Prospective Case‐Series. Clinical Oral Implants Research, 36(10), 1234-1247. https://doi.org/10.1111/clr.14469

Vancouver

Elena C, Nikos M, Iro P, Sara T, Nikolaos D. Radiographic Peri‐Implant Bone Changes in Osteoporotic Women Treated With a Ti‐Zr, Bone Level Tapered Implant With a Hydrophilic Surface: A 12‐Month Prospective Case‐Series. Clinical Oral Implants Research. 2025;36(10):1234-1247. doi:10.1111/clr.14469

BibTeX
@article{Elena2025,
  author = {Elena, Calciolari and Nikos, Mardas and Iro, Palaska and Sara, Tagliaferri and Nikolaos, Donos},
  title = {Radiographic Peri‐Implant Bone Changes in Osteoporotic Women Treated With a Ti‐Zr, Bone Level Tapered Implant With a Hydrophilic Surface: A 12‐Month Prospective Case‐Series},
  journal = {Clinical Oral Implants Research},
  year = {2025},
  volume = {36},
  number = {10},
  pages = {1234--1247},
  doi = {10.1111/clr.14469}
}
Kostenlos starten →