EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Concurrent Validity and Test–Retest Reliability of a Smartphone-Based Markerless System

Kristen F Nicholson iD, Jared J Duane, William Carter, Garrett Fernandez, Jakob Wolf, Robert J Butler, Garrett S Bullock iD

Sensors · 21.06.2026 · 26 (12) · 3934

DOI: 10.3390/s26123934 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 21.06.2026. Verfasst von Kristen F Nicholson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Wake Forest University School of Medicine, Winston-Salem, NC 27101, USA. Hauptthemen laut MEDLINE: Smartphone. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasing the accessibility and portability of precise biomechanical data to sports scientists can assist in making data-driven decisions. The purpose of this study was: (1) Assess the concurrent and convergence validity of discrete and continuous waveform biomechanics of a smartphone-based markerless system. (2) Assess test–retest reliability of the smartphone-based markerless system. Movements were recorded simultaneously with two iPhones using Uplift Labs computer vision software and with Qualisys, a 12-camera marker-based motion capture system. Each participant performed two evaluations, one week apart, consisting of two countermovement jumps. Nested Bland–Altman limits of agreement (LOA), mixed-effect linear regressions, and intraclass correlation coefficients (ICC) were calculated. Twenty participants were included [Age: 24.7 (6.6) years. Height: 178.3 (4.3) cm. Mass: 86.5 (12.4) kg. Dominant Arm (Right): 17 (85%)]. Concurrent validity (LOA: 11.8 (4.4, 19.1)) demonstrated different results compared to convergence validity (Beta: 0.87 (0.68, 1.0)) and test–retest reliability (ICC: Uplift: 95.5 (90.9, 97.8). Qualisys: 94.4 (88.5, 97.3)). Uplift demonstrated greater than the a priori-determined limits of agreement across the CMJ. However, convergence validity was acceptable. Reliability suggests Uplift could be useful for tracking performance within individual athlete sessions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneHumansMotion CaptureReproducibility of ResultsBiomechanical PhenomenaAdultMovementFemaleYoung Adult

Stichwörter der Autor:innen

biomechanicscountermovement jumpcriterion validityrange of motion

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Wake Forest University School of Medicine, Winston-Salem, NC 27101, USA.
  • Department of Biomedical Engineering, Wake Forest University School of Medicine, Winston-Salem, NC 27101, USA.
  • Nashville Soccer Club, Nashville, TN 37203, USA.
  • Department of Biostatistics and Data Science, Wake Forest University School of Medicine, Winston-Salem, NC 27101, USA.
  • Centre for Sport Injury Prevention Research, University of Calgary, Calgary, AB T2N 1N4, Canada.

ORCID-Profile: Kristen F Nicholson, Garrett S Bullock

Zitieren

APA

Nicholson, K. F., Duane, J. J., Carter, W., Fernandez, G., Wolf, J., Butler, R. J., & Bullock, G. S. (2026). The Concurrent Validity and Test–Retest Reliability of a Smartphone-Based Markerless System. Sensors, 26(12), 3934. https://doi.org/10.3390/s26123934

Vancouver

Nicholson KF, Duane JJ, Carter W, Fernandez G, Wolf J, Butler RJ, et al. The Concurrent Validity and Test–Retest Reliability of a Smartphone-Based Markerless System. Sensors. 2026;26(12):3934. doi:10.3390/s26123934

BibTeX
@article{Nicholson2026,
  author = {Nicholson, Kristen F and Duane, Jared J and Carter, William and Fernandez, Garrett and Wolf, Jakob and Butler, Robert J and Bullock, Garrett S},
  title = {The Concurrent Validity and Test–Retest Reliability of a Smartphone-Based Markerless System},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {12},
  pages = {3934},
  doi = {10.3390/s26123934}
}
Kostenlos starten →