EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Concurrent Validity and Test–Retest Reliability of Pressure-Detecting Insoles for Static and Dynamic Movements in Healthy Young Adults

Johanna Lambrich iD, Marco Hagen, Gerrit Schwiertz, Thomas Muehlbauer iD

Sensors · 19.05.2023 · 23 (10) · 4913

DOI: 10.3390/s23104913 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.05.2023. Verfasst von Johanna Lambrich und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Movement and Training Sciences/Biomechanics of Sport, University of Duisburg-Essen, 45141 Essen, Germany. Hauptthemen laut MEDLINE: Bone Plates, Health Status. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Duisburg-Essen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compared to force-plates, pressure-detecting insoles have the advantage that vertical ground reaction force (vGRF) can be estimated under field rather than laboratory conditions. However, the question arises whether insoles also provide valid and reliable results compared to a force-plate (i.e., the gold standard). The study aimed to investigate the concurrent validity and test–retest reliability of pressure-detecting insoles during static and dynamic movements. Twenty-two healthy young adults (12 females) performed standing, walking, running, and jumping movements while simultaneously collecting pressure (GP MobilData WiFi, GeBioM mbH, Münster, Germany) and force (Kistler®) data twice, 10 days apart. Concerning validity, ICC values showed excellent agreement (ICC > 0.75), irrespective of the test condition. Further, the insoles underestimated (mean bias: −4.41 to −37.15%) most of the vGRF variables. Concerning reliability, ICC values for nearly all test conditions also showed excellent agreement, and the SEM was rather low. Lastly, most of the MDC95% values were low (≤5%). The predominantly excellent ICC values for between-devices (i.e., concurrent validity) and between-visits (i.e., test–retest reliability) comparisons suggest that the tested pressure-detecting insoles can be used under field-based conditions for a valid and reliable estimation of relevant vGRF variables during standing, walking, running, and jumping.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone PlatesHealth StatusYoung AdultFemaleHumansReproducibility of ResultsGermanyLaboratories

Stichwörter der Autor:innen

force platejumpingpressure insolerepeatabilityrunningstandingvalidationwalking

Autor:innen und Institutionen

  • Division of Movement and Training Sciences/Biomechanics of Sport, University of Duisburg-Essen, 45141 Essen, Germany.

ORCID-Profile: Johanna Lambrich, Thomas Muehlbauer

Förderung

  • University of Duisburg-Essen

Zitieren

APA

Lambrich, J., Hagen, M., Schwiertz, G., & Muehlbauer, T. (2023). Concurrent Validity and Test–Retest Reliability of Pressure-Detecting Insoles for Static and Dynamic Movements in Healthy Young Adults. Sensors, 23(10), 4913. https://doi.org/10.3390/s23104913

Vancouver

Lambrich J, Hagen M, Schwiertz G, Muehlbauer T. Concurrent Validity and Test–Retest Reliability of Pressure-Detecting Insoles for Static and Dynamic Movements in Healthy Young Adults. Sensors. 2023;23(10):4913. doi:10.3390/s23104913

BibTeX
@article{Lambrich2023,
  author = {Lambrich, Johanna and Hagen, Marco and Schwiertz, Gerrit and Muehlbauer, Thomas},
  title = {Concurrent Validity and Test–Retest Reliability of Pressure-Detecting Insoles for Static and Dynamic Movements in Healthy Young Adults},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {10},
  pages = {4913},
  doi = {10.3390/s23104913}
}
Kostenlos starten →