Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B
Journal of Dental Biomechanics · 2014
DOI: 10.1177/1758736014547143 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dental Biomechanics, 2014. Verfasst von Antoine Berberi und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, Lebanese University, Beirut, Lebanon. Die Arbeit wurde bisher 17-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Leakage has been addressed as a major contributing factor to inflammatory reactions at the implant-abutment connection, leading to problems such as oral malodor, inflammation, and marginal bone loss. The aim of this study was to investigate in vitro the leakage at implant-abutment interface of OsseoSpeed™ implants connected to original and compatible abutments. A total of 28 OsseoSpeed implants were divided into four groups (n = 7). Each group was connected to four different abutments according to manufacturers' recommendations: group A (TiDesign™); group B (Natea™); group C (Dual™); and group D (Implanet™) abutments. The inner volume of each implant-abutment combination was calculated and leakage was detected for each group with spectrophotometric analysis at 1 h (D0) and 48 h (D1) of incubation time using Rhodamine B. At 1 h, leakage volume was significantly lower in TiDesign and Dual than in Natea and Implanet (P < 0.001). At 48 h, however, leakage was significantly lower between TiDesign and all other systems (P < 0.005). Compatible abutments do not fit internal connection of OsseoSpeed implants perfectly, which increases the leakage of the final assembly.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Dentistry, Lebanese University, Beirut, Lebanon.
- Ecole Doctorale, PRASE, Lebanese University, Beirut, Lebanon.
Zitieren
APA
Berberi, A., Tehini, G., Rifai, K., Bou Nasser Eddine, F., Badran, B., & Akl, H. (2014). Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B. Journal of Dental Biomechanics. https://doi.org/10.1177/1758736014547143
Vancouver
Berberi A, Tehini G, Rifai K, Bou Nasser Eddine F, Badran B, Akl H. Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B. Journal of Dental Biomechanics. 2014. doi:10.1177/1758736014547143
BibTeX
@article{Berberi2014,
author = {Berberi, Antoine and Tehini, George and Rifai, Khaldoun and Bou Nasser Eddine, Farah and Badran, Bassam and Akl, Haidar},
title = {Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B},
journal = {Journal of Dental Biomechanics},
year = {2014},
doi = {10.1177/1758736014547143}
}
EUVIMED